1 PLC Connection Guide AIBUS ...
ControlLogix, CompactLogix CPU CH0 setting: Create the Tag: 10
100 LS XGB/XGT TCP/IP series LS XGB/XGT TCP/IP Series http://www.lgis.com/ HMI Setting: Parameters Recommend Option Notes PLC type XBL-EMTA
Wiring diagram: Ethernet: MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 101 1 TX+ White/Orange 1 RX+ 1 8 2 TX- Orange 2 RX- RJ
102 LIYAN EX series LIYAN PLC Ex/Ex1s/Ex1n/Ex2n series http://www.liyanplc.com/ HMI Setting: Parameters Recommend Option Notes PLC type Mitsubish
Wiring diagram: Ex,Ex1s,Ex1n,Ex2n series RS232 LIYAN Ex series 103 MT8000 RS232 9P D-SUB COM1 COM2 COM3 CPU RS232 Port 8P miniDin Female 3 TX 4
Master (Master-Slave Protocol) To connect MT8000 with MT500, MT500 has to set as [Slave]. HMI Setting: Parameters Recommend Option Notes PLC typ
Device address: Bit/Word MT500 MT8000 Range Memo 105 B Ms_RB RW_Bit ddd:0~4095 (h): 0~f B Ms_LB LB dddd:0~9999 W Ms_RW RW ddd:0~65535 W
106 Driver Version: Version Date Description of Changes V1.00 Dec/30/2008
107 Memobus (YASKAWA MP Series controllers) YASKAWA MP2200, MP2300, MP2300S, MP9xx communication module http://www.yaskawa.com/ HMI Setting: Parame
Wiring diagram: 1. RS-232: 217IF-01, 218IF-01 217IF-01 RS232 MT8000 RS232 9P D-SUB Female COM1 COM2 COM3 3 TX 4 TX 7 TX 3 RX 2 RX 6
Ethernet: Direct connect (crossover cable) MT8000 Wire color Ethernet Module RJ45 Ethernet RJ45 1 TX+ White/Orange 3 RX+ 2 TX- Orange 6 RX- 3
Driver Version: Version Date Description of Changes V1.20 Dec/30/2008 11
3. Close all dialogs and save to MP2300S. Note: 1. Only CNO 01 able to auto communication with one HMI. other CNO need create ladder program to co
111 Memory Map protocol Memory Map protocol is similar to IBM 3764R communication protocol. The MT8000 reserves 512 words of Data memory for use with
112 RS-485 4W: MT8000 RS485 9P D-SUB MT8000 RS485 9P D-SUB 1 RX- 3 TX- 2 RX+ 4 TX+ 3 TX- 1 RX- 4 TX+ 2 RX+ 5 GND 5GND NOTE : For Memory map inf
113 MITSUBISHI A1S MITSUBISHI A1S http://www.mitsubishi-automation.com/ HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI A1S Co
Wiring diagram: Use the RS422 to RS232 PLC programming cable (show as follows) MITSUBISHI AnS CPU Mitsubishi MT8000 PLC programming C
115 Driver Version: Version Date Description of Changes V1.00 Sep/18/2009
116 MITSUBISHI A2A MITSUBISHI A2A http://www.mitsubishi-automation.com/ HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI A2A Co
Wiring diagram: Use the RS422 to RS232 PLC programming cable (show as follows) MITSUBISHI AnS CPU Mitsubishi MT8000 PLC programming Ca
118 Driver Version: Version Date Description of Changes V1.00 Aug/12/2009
119 MITSUBISHI A2US MITSUBISHI A2US http://www.mitsubishi-automation.com/ HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI A2US
12 Allen-Bradley DF1 Allen-Bradley MicroLogix 1000, 1100, 1200, 1500, SLC 5/03, 5/04, 5/05 http://www.ab.com HMI Setting: Parameters Recommend Opti
MITSUBISHI AnS CPU Mitsubishi MT8000 PLC programming Cable RS-422 COM1 RS232 9P D-SUB FemaleDB25 Male 2 RX+ RD 3 TD 3 TX+ TD 2 RD
121 MITSUBISHI A3N/A1SH MITSUBISHI A3N/A1SH http://www.mitsubishi-automation.com/ HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI
Wiring diagram: Use the RS422 to RS232 PLC programming cable (show as follows) MITSUBISHI AnS CPU Mitsubishi MT8000 PLC programming Cab
123 Version Date Description of Changes V1.00 Oct/20/2009
124 MITSUBISHI AJ71 Mitsubishi A series PLC with AJ71C24 communication module using the Computer Link protocol. http://www.mitsubishi-automation.com H
125 Wiring diagram: RS-485 4W: MT800 Com1 RS-485] 9P D-SUB AJ71C24 RS-422 1 RX- SDB 2 RX+ SDA 3 TX- RDB 4 TX+ RDA 5 GND GND RS-232: A1SJ71UC
126 MITSUBISHI MELSEC-Q (Ethernet) MITSUBISHI Q series, MELSEC-Q protocol application to CPU of Ethernet interface or Ethernet module. http://www.mits
W D ddddd 0 ~ 12287 Data Register W W hhhh 0 ~ 1FFF Link Register W TN dddd 0 ~ 2047 Timer Current value W SN dddd 0 ~ 2047 Retentive
MITSUBISHI Q series Ethernet module setting: 1. Click PLC parameter 2. Built-in Ethernet port. 3. Click Open settings and then set the IP ad
129 MITSUBISHI FX0n/FX2 Mitsubishi FX0s/FX0n/FX1s/FX2 PLC http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC
Bit/Word Device Type Format Range Memo 13 W CfnPV fffddd File no. fff: 5, 10~254 Counter Accumulator Value Element no. ddd:0~254 N7 ddd ddd:0~2
W SD ddd 8000-9999 Special Data Register Wiring diagram: MT8000 Mitsubishi PLC CPU RS422 Port COM1 [RS-485] 4w8Pin miniDin Female 9P D-SUB 8
131 MITSUBISHI FX2n Mitsubishi FX1n/FX2n series PLC http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type
Device Bit/Word Format Range Memo Type W CV ddd 0-199 Counter Memory W D ddd 0-7999 Data Register DW CV2 ddd 200-255 Counter Memory(D Word
MITSUBISHI FX232/485BD Mitsubishi FX0n/FX2/FX2n COM For Communication Module BD FX2N-485-BD, FX2N-232-BD, FX1N-485-BD and FX1N-232-BD http://www.mitsu
134 Device address: Bit/Word Device Type Format Range Memo B X ooo 0-377 Input Relay B Y ooo 0-377 Output Relay B M ddd 0-9999 Auxiliary Relay
135 Communication Module RS485BD: MT8000 RS-485 2Wire 9P D-SUB RS485BD Module 5P terminal COM1 COM3 1 RX- 6 Data- SDB 2 RX+ 9 Data+ SDA 3
136 MITSUBISHI FX3U Mitsubishi FX3U/FX3UC http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI
Device Bit/Word Format Range Memo Type W TV ddd 0~511 Timer Memory (T) W CV ddd 0~199 Counter Memory (C) DW CV2 ddd 200~255 Counter Mem
138 MITSUBISHI FX3U-ETHERNET MITSUBISHI FX SERIES, Module: FX3U-ENET http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option
Wiring diagram: Ethernet: MT8000 Wire color Ethernet Hub or Switch RJ45 Ethernet RJ45 1 TX+ White/Orange 1 RX+ 2 TX- Orange 2 RX- 3 RX+
Allen-Bradley DH485 Allen-Bradley MicroLogix 1000, 1100, 1200, 1500, SLC 5/03, 5/04, 5/05 http://www.ab.com HMI Setting: Parameters Recommend Optio
Fx3u-ENET module setting: Before using Ethernet module, using GX Developer / FX Configurator-EN to set the Ethernet module, the FX3u-ENET module setti
4. After finishing the PLC settings, select Tools/FX special function utility/FX Configurator-EN 5. Select “Module 0” in Ethernet Module settings.
6. In Ethernet operational settings, select the related parameters and IP address and then press ”End” to finish the settings. 7. In Ethernet open
(The first Protocol means using GX Developer to communicate with module, The max. “Fixed buffer communication preocedure” is 4 units.) 8. After se
144 Driver Version: Version Date Description of Changes V1.00 Feb/12/2009
145 MITSUBISHI Q00J CPU MITSUBISHI Q00J CPU HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI Q00J Com port RS-232 C
Wiring diagram: RS-232: MT8000 RS232 9P D-SUB Q00 CPU port 146 COM1 COM2 COM3 Mini-DIN 6pin3 TX 4 TX 7 TX 3 RXD 2 RX 6 RX 8 RX 4 TXD
147 MITSUBISHI Q02H Mitsubishi Q02H CPU port. http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type MITSUB
Bit/Word Device Type Format Range Memo B CC ddd 0~1023 Counter Coil B SB hhh 0~7FF Special Link Relay B S dddd 0~8191 Step Relay B DX hhh
149 MITSUBISHI Q01U Q02U MITSUBISHI Q01U, Q02U CPU HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI Q02U Com port RS232 RS
15 Device address: Bit/Word Device Type Format Range Memo B I1 ddd(dd) ddd:0~254 (dd): 0~15 Input (I) B O0 ddd(dd) ddd:0~254 (dd): 0~15
Wiring diagram: RS-232: MT8000 RS232 9P D-SUB Q02 CPU port Mini-DIN 6pin COM1 COM2 COM3 3 TX 4 TX 7 TX 4 RXD 2 RX 6 RX 8 RX 3 TXD MINI-D
151 MITSUBISHI Q01U Q02U USB MITSUBISHI Q01U, Q02U USB Port HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI Q02U Com port
152 Driver Version: Version Date Description of Changes V1.00 Feb/09/2010
153 MITSUBISHI Q06H Mitsubishi Q06H CPU port. http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type MITSUB
Bit/Word Device Type Format Range Memo B CS ddd 0~1023 Counter Contact B CC ddd 0~1023 Counter Coil B SB hhh 0~7FF Special Link Relay B S d
MITSUBISHI QJ71 Mitsubishi Q series PLC with QJ71C24 communication module, Q00, Q01, Q00UJ CPU port. http://www.mitsubishi-automation.com HMI Setti
Device address: Bit/Word Device Type Format Range Memo B X hhh 0~1FFF Input Relay B Y hhh 0~1FFF Output Relay B M dddd 0~8191 Internal Relay
Bit/Word Device Type Format Range Memo W R ddddd 0~32767 File Register W SW hhh 0~7FF Special Link Register W Z d 0~9 Index Register W ZR h
158 Driver Version: Version Date Description of Changes V1.20 Dec/30/2008
159 MITSUBISHI QJ71E71 Mitsubishi Q type, QJ71E71-100 Ethernet module. http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Opt
Wiring diagram: RS-485: SLC500 Fixed type, SLC5/01,02,03 CH1. MT8000 can’t connect to 1747-AIC PERIPHERAL PORT
Wiring diagram: Ethernet: MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 1 TX+ White/Orange 1 RX+ 2 TX- Orange 2 RX- 3 RX+
QJ71E71-100 Ethernet module settings: 1. Use Q-CPU’s USB or RS232 setting PLC parameters. 2. Click Operational setting to set IP information. 161
3. Select Ethernet (2.0) for communicating with HMI. 4. Click “Open settings” to set the system. 162
5. Press END to finish settings. 163
6. EAD FROM PLC], click QCPU(Qmode) and press OK. Restart PLC software and select [R 7. Select “Ethernet board” in PC Side I/F to set Network and S
9. the clic Other station(Single network)” setting “Check at communication time” and “Retry times”. In “O r station”, k “ After finishing settings
166 MODBUS ASCII MODBUS ASCII CONTROLLER http://www.modbus.org HMI Setting: Parameters Recommend Option Notes PLC type Modbus ASCII Com port
167 Modbus RTU function code: 0x 0x01 Read coil 0x05 write single coil 1x 0x02 Read discrete input N/A for write op
168 Driver Version: Version Date Description of Changes V1.40 Apr/17/2009
169 MODBUS RTU MODBUS RTU CONTROLLER http://www.modbus.org HMI Setting: Parameters Recommend Option Notes PLC type Modbus RTU Com port RS485
17 Allen-Bradley EtherNet/IP CompactLogix Allen-Bradley ControlLogix, CompactLogix, FelxLogix Ethernet http://www.ab.com HMI Setting: Parameters Rec
170 NOTE: Address type “5x” are mapping to Hold Reg. The communication protocol of 5x is almost same as “4x” except “5x”making double word swap. If 4x
171 MODBUS RS422/485 PORT MT8000 COM1 RS-485 4w Modbus RTU Controller RS422 Port 1 RX- TX- 2 RX+ TX+ 3 TX- RX- 4 TX+ RX+ 5 GND GND MT
172 MODBUS RTU (zero-based addressing) MODBUS RTU CONTROLLER http://www.modbus.org HMI Setting: Parameters Recommend Option Notes PLC type Modbus
173 NOTE: Address type “5x” are mapping to Hold Reg. The communication protocol of 5x almost same as “4x” except “5x”making double word swap. If 4x ha
174 MODBUS RS422/485 PORT MT8000 COM1 RS-485 4w Modbus RTU Controller RS422 Port 1 RX- TX- 2 RX+ TX+ 3 TX- RX- 4 TX+ RX+ 5 GND GND MT
Driver Version: Version Date Description of Changes V1.30 Aug/26/2009 175
176 MODBUS SERVER (Modbus RTU Slave) HMI Setting: Parameters Recommend Option Option Notes PLC type Modbus Server Com port RS232 RS232, R
177 Wiring diagram: RS-232: MT8000 RS232 9P D-SUB Modbus RTU RS232 9P D-SUB COM1 COM2 COM3 3 TX 4 TX 7 TX RX 2 RX 6 RX 8 RX TX 5 GND 5
178 MODBUS TCP/IP Modbus RTU TCP/IP device. http://www.modbus.org HMI Setting: Parameters Recommend Option Notes PLC type MODBUS TCP/IP Com po
Wiring diagram: Ethernet:: MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 1 TX+ White/Orange 1 RX+ 1 8 2 TX- Orange 2 RX- RJ45
Element no. ddd: 0~255 Tx.ACC fffddd File no. fff: 4, 10~255 Timer Accumulator Value (T4, T10~255) DW Element no. ddd: 0~255 Cx.PRE fffddd File n
MODBUS TCP/IP (zero-based) Modbus RTU TCP/IP device. http://www.modbus.org HMI Setting: Parameters Recommend Option Notes PLC type MODBUS TCP/IP
181 Ethernet: Direct connect (crossover cable) MT8000 Ethernet RJ45 Wire color Modbus TCP Device RJ45 1 TX+ White/Orange 3 RX+ 2 TX- Orange 6
HMI Setting: 182 Parameters Recommend Option Notes PLC type Modbus RTU Support Extended Address mode. Com port RS485 RS232/RS485 Must match th
183 COM1 COM3 1 RX- 6 Data- 2 B(-) 2 RX+ 9 Data+ 1 A(+) 5 GND 5 GND 5 DTP 7 GND 8Pin miniDin Female MT8000 RS-485 9P D-SUB COM1 CO
184 http://oeiweb.omron.com/oei/Products-PLC.htm HMI Setting: Parameters Recommend Option Notes PLC type OMRON C/CQM1 Series Com port RS232 R
185 Wiring diagram: CPU Port(CPM2A,CQM1/1H,C200H/HS/ALPHA series) Communication Module: CPM1-CIF01 adapter(for CPM1/CPM1A/CPM2A series,CQM1/CQM1H se
186 OMRON CJ1/CS1 OMRON CP1L, CP1H, CJ1M, CJ1H, CJ1G, CS1H and CS1G. (Host Link Protocol FINS command), this driver supports Extend Addressing mode. h
Bit/Word Device Type Format Range Memo ddd:0~511 Word W ddd Work Area (WR) Word CIO ddd ddd:0~6143 Channel I/O (CIO) Word A ddd ddd:0~959
188 OMRON CJ1/CS1 Ethernet OMRON CJ1M, CJ1H, CJ1G, CS1H and CS1G. (Ethernet FINS), http://oeiweb.omron.com/oei/Products-PLC.htm HMI Setting: Parame
Wiring diagram: Ethernet: MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 1 TX+ White/Orange 1 RX+ 2 TX- Orange 2 RX- 3 RX+ Whit
19 Driver Version: Version Date Description of Changes V1.10 Dec/30/2008
190 7 BD3+ White/Brown 7 BD3+ 8 BD3- Brown 8 BD3- Driver Version: Version Date Description of Changes V1.00 Dec/30/2008
191 OMRON E5CN OMRON E5CN series Temperature controller with communication option. E5EN/CN/GN series http://oeiweb.omron.com HMI Setting: Parameters
192 Bit/Word Device Type Format Range Memo W Operation02_01 hh 0 Multi-SP Set point 1 W Operation02_02 hh 0 Multi-SP Set point 2 W Operat
193 Panasonic FP NAIS(Matsushita) FP series include FP-X, FP-Σ, FP0, FP1, FP2, FP2SH, FP10SH and FP3 Ethernet support FP-X with AFPX-COM5. http://pewa
W DT ddd 0~32767 Data Register(DT) W LD dddd 0~8447 Link Register(LD) W WX dddd 0~9999 Input(WX) (read only) W WY dddd 0~9999 Output(WY) W WR dd
D-SUB 1 RX- 2 TXDA 2 RX+ 5 TXDB 3 TX- 3 RXDA 4 TX+ 6 RXDB Hirose 8Pin Port 5 GND 1 GND MT8000 FP3 CPU RS422 portCOM1[RS-485]4w 9P D-SUB
Driver Version: Version Date Description of Changes V1.40 Jul/23/2009 196
197 Panasonic MINAS A4 Series Panasonic MINAS A4 series Servo Drive HMI Setting: Parameters Recommend Option Notes PLC type PANASONIC MINAS A4
198 (Numeric format: 16-bit Unsigned) W Command 92 d 1 ~ 14 Batch Alarm (Note 4) (Numeric format: 16-bit Unsigned) W Command 93 d 0 ~ 0 clear al
MINAS A4 Driver 199 CNX3 Port MINAS A4 Driver CNX4 Port 7 D- 3 TX 8 D+ 5 RX 4 GND 4 GND 7 D- 8 D+ 8P Mini-
2 LS MASTER-K Cnet... 92 LS MASTER-K10S1 .
20 Allen-Bradley EtherNet/IP (DF1) Allen-Bradley MicroLogix 1100, 1400, SLC5/05 Ethernet port. MicroLogix1000, 1200, 1500, SLC 5/03, 5/04 with 1761-NE
200 Driver Version: Version Date Description of Changes V0.01 Jul/23/2009
201 Parker Compax3 Parker Compax3 Servo Drive http://www.parker.com HMI Setting: RS232 Parameters Recommend Option Notes PLC type Parker Compax3
read/write address: 400.1, please input 40001. When select the Register_Float, be sure set data format to 32 bit float, or it will ignore th
3. Setting parameters as below 4. Downloading settings to Compax3 Servo. 5. Setting EB8000 system parameter and connecting with PLC for communicat
204 Parker SLVD Servo Parker SLVD Servo, SLVD1N, SLVD2N, SLVD5N, SLVD7N, SLVD10N, SLVD15N, SLVD17N. http://www.parker.com/portal/site/PARKER/ HMI Set
205 Device address: Bit/Word Device Type Format Range Memo B Par_Binary DDD(DD) 0~4999(15) Set a bit of Parameter W Par_One_Word DDD 0~4999
206 SAIA PCD PGU mode SAIA PCD series PGU mode. http://www.saia-burgess.com/ HMI Setting: Parameters Recommend Option Notes PLC type SAIA PCD PGU
207 Wiring diagram: RS232: MT8000 RS232 9P D-SUB Male COM1 COM2 COM3 SAIA PCD PGU port 9P D-SUB Female 3 TX 2 RXD 2 RX 3 TXD 5 GND
208 SAIA PCD S-Bus mode SAIA PCD series S-Bus mode. http://www.saia-burgess.com/ HMI Setting: Parameters Recommend Option Notes PLC type SAIA PC
209 Wiring diagram: RS232: MT8000 RS232 9P D-SUB Male COM1 COM2 COM3 SAIA PCD PGU port 9P D-SUB Female 3 TX 4 TX 7 TX 2 RXD 2 RX 6 RX 8
File no. fff:0~254 Floating point data file (F8, 10~254)32bit Float Ffn fffddd Element no. ddd:0~254 File no. fff:0~254 Driver version 2.00 or abo
210 Schleicher XCX20C Schleicher XCx-Systems Ethernet port. Schleicher XCS series, 20C model http://www.schleicher-electronic.com HMI Setting: Paramet
Wiring diagram: Schleicher XCS20 MT8000 RS232 RS-232 X1 9P D-SUB Female 9P D-SUB Male COM1 COM2 COM3 3 TX 4 TX 7 TX 2 RD 2 RX 6 RX 8
Schleicher XCX 300 (Ethernet) Schleicher XCx-Systems Ethernet port. http://www.schleicher-electronic.com HMI Setting: Parameters Recommend Option N
Wiring diagram: Ethernet: Direct connect (crossover cable) MT8000 Ethernet RJ45 Wire color PLC RJ45 1 TX+ White/Orange 3 RX+ 2 TX- Orange 6 RX-
SEW Eurodrive MOVITRAC SEW Eurodrive series, model MOVITRAC-07 inverter, MovitracB http://sg.sew-eurodrive.com/ HMI Setting: Parameters Recommend O
215 Driver Version: Version Date Description of Changes V1.20 Dec/30/2008
216 SIEMENS S7/200 Siemens S7/200 series PLC (CPU212/214/215/216/221/222/224/226/226XM) http://www.ad.siemens.com HMI Setting: Parameters Recommend
217 W VW_Odd ddddd 0-10239 V memory DW VD ddddd 0-10239 V memory double word DW VD_Odd ddddd 0-10239 V memory double word W VD_String ddddd
218 SIEMENS S7/200 Ethernet Siemens S7/200 Ethernet Series PLC(CPU212/214/215/216/221/222/224/226/226XM) http://www.ad.siemens.com HMI Setting: Param
RJ45 connector Ethernet: Direct connect (crossover cable) Wire color Ethernet Device MT8000 Ethernet RJ45 RJ45 1 TX+ White/Orange 3 RX+ 2 TX-
Ethernet: MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 1 TX+ White/Orange 1 RX+ 2 TX- Orange 2 RX- 3 RX+ White/Green 3 TX+
220 SIEMENS S7/300 Siemens S7/300 series PLC http://www.ad.siemens.com HMI Setting: Parameters Recommend Option Notes PLC type SIEMENS S7/300
221 Wiring diagram: MT8000 RS232 9P D-SUB Male COM1 COM2 COM3 SIEMENS S7/300 PC adapter RS232 Port 9P D-SUB Male 3 TX 4 TX 7 TX 2 RXD 2 RX
222 SIEMENS S7/300 Ethernet Siemens S7/300 Ethernet Series PLC http://www.ad.siemens.com HMI Setting: Parameters Recommend Option Notes PLC type
Wiring diagram: Ethernet Hub or Switch RJ45 Wire color MT8000 Ethernet RJ45 1 TX+ White/Orang 1 RX+ 2 TX- Orange 2 RX- 3 RX+ White/Green
224 SIEMENS S7/300 MPI Siemens S7/300 series PLC http://www.ad.siemens.com HMI Setting: Parameters Recommend Option Notes PLC type SIEMENS S7/300
225 Wiring diagram: MT8000iV series HMI RS485 2w 9P D-SUB Male COM1 COM3 S7-200 PPI / 9P D-SUB MaleS7-300 MPI / 9P D-SUB Male1 RX- 6 Data- 8 D
226 SIMATIC TI505 SIMATIC TI505 Series PLCs: TI520, TI525, TI530, TI535, TI545, TI555, TI560, TI565, TI575 Using the NITP protocol in a point-to-point
227 Wiring diagram: RS-232: MT8000 HMI 9P D-SUB COM1 [RS232] COM2 [RS232] COM3 [RS232] SIMATIC TI505 25Pin D-SUB 3 TX 4 TX 7 TX 3 RXD 2 RX
228 Driver Version: Version Date Description of Changes V1.10 Apr/22/2009
229 TECO (TAIAN TP03) TECO (TAIAN TP03) series PLC http://www.teco.com.tw/sa/en/ HMI Setting: Parameters Recommend Option Notes PLC type TAIAN TP
23 Allen Bradley PLC5 http://www.ab.com HMI Setting: Parameters Recommend Option Notes PLC type AB PLC5 Com port RS232 Baud rate 19200 9
Wiring diagram: MT8000 RS-485 4w TP03 PC/PDA port 9P D-SUB 8 Pin mini DIN 1 RX- 4 TX- 2 RX+ 7 TX+ 8 Pin mini DIN Female 5 GND 3
231 Telemecanique UniTelWay Modicon TSX Micro&Nano&Neza series PLC http://www.modicon.com HMI Setting: Parameters Recommend Option Notes P
Wiring diagram: TSX37-XX/TSX07-XX CPU TSX series CPU port 8P mini-din Female MT8000 RS-485 9P D-SUB COM1 COM3 1 RX- 6 Data- 2 D- 8Pin miniDin
233 TOSHIBA T series Toshiba T series, S2E http://www.tic.toshiba.com HMI Setting: Parameters Recommend Option Notes PLC type Toshiba T Serial
Wiring diagram: RS232 MT8000 RS232 9P D-SUB Toshiba T1 PRG port 8P mini-D COM1 COM2 COM3 234 3 TX 4 TX 7 TX 8 RXD 2 RX 6 RX 8 RX 6 TXD
235 TOSHIBA TC mini series TOSHIBA MACHINE CO., JAPAN Web Site: http://www.toshiba-machine.co.jp HMI Setting: Parameters Recommend Option Notes PL
236 Wiring diagram: RS232 MT8000 HMI RS232 9P D-SUB COM1 COM2 COM3 TC mini series 9P D-SUB 3 TX 4 TX 7 TX 3 RXD 2 RX 6 RX 8 RX 2 TXD
237 TOSHIBA VF-S11 Toshiba Invertor Protocol(ASCII code) HMI Setting: Parameters Recommend Option Notes PLC type Toshiba VF-S11 Com port RS48
Wiring diagram: Pay Attention: Before you connect the VF-S11, make sure you to put both switches of SW1 to the related position. (SW1: Wiring method s
239 Driver Version: Version Date Description of Changes V1.20 Aug/31/2009
24 Allen-Bradley PLC-5 Family PLCs using the DF1 Full Duplex protocol. For the PLC-5/10, PLC-5/15 and PLC-5/25 the MT8000 should be connected to: z
240 VIGOR VIGOR M Series http://www.vigorplc.com.tw/ HMI Setting: Parameters Recommend Option Notes PLC type VIGOR Com port RS232 RS232, RS4
241 Wiring diagram: RS-485 4wire: MT8000 COM1 RS485 4w 9P D-SUB Male VIGOR M series 6pin terminal 1 RX- TX- 2 RX+ TX+ 3 TX- RX- 4 TX+
242 YASGAWA SMC3010 YASKAWA SMC Series Servo Motor Controller HMI Setting: Parameters Recommend Option Notes Device type YASKAWA SMC 3010 Com p
243 Bit/Word Device Type Format Range Memo W EC d 0 ~ 2 DW EM d 0 ~ 4 W ER d 0 ~ 2 W FA d 0 ~ 2 DW FL d 0 ~ 4 W FV d 0 ~ 2
244 *2 User define integer variable V000~V999, floating point variable F000~F999. Wiring diagram: MT8000 RS232 9P D-SUB COM1 COM2 COM3 SMC3010 CN
YAMAHA ERCD HMI Setting: 245 Device address: Bit/Word Device type Format Range Memo Word P ddd 0-999 Read/Write, PNT point d
Write only,X+ command Word X_ADD ddd 0 Write only,X- command Word X_SUB ddd 0 Wiring diagram: MT8000 PB( RS232) COM1(RS232) 246
247 Yokogawa FA-M3 FA-M3 CPU SP35-5N, SP55-5N CPU port, F3LC11 Computer Link module. http://www.yokogawa.com/itc/itc-index-en.htm HMI Setting: Parame
248 Wiring diagram: RS-232: CPU port MT8000 RS232 CPU port cable 9P D-SUB
P.S Because use Personal computer link, when you connecting to PLC it will delay about 20sec for test communication. How to Setting YOKOGAWA PLC Com
25 Altus ALNET-I Altus SeriesMode : PO3042, PO3142, PO3242, PO3342, PL103 ,PL104, PL105, QK800, QK801, QK2000. HMI Setting: Parameters Recommend Opt
click “Configuration” for setup communication. 250
251
Driver Version: Version Date Description of Changes V1.10 Jan/01/2009 252
Yokogawa FA-M3 (Ethernet) FA-M3 CPU SP35-5N, SP55-5N with F3LE01-5T/F3LE11-0T Ethernet module. http://www.yokogawa.com/itc/itc-index-en.htm HMI Setti
Device address: Bit/Word Device Type Format Range Memo ddd B X 201-71664(discontinuous) ddd B Y 201-71664(discontinuous) ddd B I 1-16384 ddd
255 Driver Version: Version Date Description of Changes V1.00 Dec/30/2008
MT6050i Com Port Connection Guide Bottom View MT6050i Pin assignment of the 9 Pin, Male, Pin assignment of the 9 Pin, Male, SUB-D, COM1 [
257 Wiring diagram: MT6050i COM1 [RS-232] 9P D-SUB Female PLC RS-232 Communication Com Port interface 9 RXD TXD 6 TXD RXD 5
Wiring diagram: PLC PO3042, PO3142, PO3242, PO3342 MT8000 RS232 9P D-SUB PLC COM1 RS232 COM1 COM2 COM3 RJ45 Port 3 TX 4 TX 7 TX 3 RX 2 R
27 Baumuller Servo http://www.baumuller.com/ HMI Setting: Parameters Recommend Option Notes PLC type Baumuller Com port RS485 4W COM1 Baud
28 Wiring diagram: RS-485 4W: MT8000 HMI COM1RS485 4W 9P D-SUB Female Baumuller servo RS-422 9P D-SUB Female 1 RX- 1 TXD- 2 RX+ 9 TXD+ 3 TX- 5
29 Cimon CM1-CP4A Cimon CM1 series, CP4A module http://www.kdtsys.com HMI Setting: Parameters Recommend Option Notes PLC type Cimon CM1-CP4A/ECO1A
3 Parker SLVD Servo ... 204 SAIA PCD PGU m
Wiring diagram: EasyView MT8000 HMI CM1-CP4A 6P RJ-11 Female 9P D-SUB COM1 [RS232] COM2 [RS232] COM3 [RS232] 3 TX 4 TX 7 TX 3 RXD 2 RX
31 Cimon CM1-SC02A Cimon CM series, SC02A module http://www.kdtsys.com HMI Setting: Parameters Recommend Option Notes PLC type Cimon CM1-SC02A
32 Wiring diagram: MT8000 RS232 9P D-SUB Female Cimon CM1-SC02A RS-232 9P D-SUB Male COM1 COM2 COM3 3 TX 4 TX 7 TX 2 RD 2 RX 6 RX 8 RX
Copley Controls Digital Servo Driver & Controllers, Xenus, Xenus Micro, Accelnet, Accelnet Micro, Stepnet series http://www.copleycontrols.com/mot
Stepnet Stepnet MT8000 RS232 RS232 RJ11 9P D-SUB J8 cable connector COM1 COM2 COM3 3 TX 4 TX 7 TX 2 RXD 2 RX 6 RX 8 RX 5 TXD 5 GND 5
35 Danfoss ECL Apex20 Controller http://www.danfoss.com/ HMI Setting: Parameters Recommend Option Notes PLC type Danfoss ECL Apex20 Com port R
36 RS485: MT8000 RS-485 9P D-SUB Female COM1 COM3 ECL Apex20 Controller Port# 1 1 RX- 6 Data- 11 2 RX+ 9 Data+ 12 MT8000 RS-485 9P D-SUB F
37 DELTA DVP DELTA DVP series http://www.deltadriver.com HMI Setting: Parameters Recommend Option Notes PLC type DELTA DVP Com port RS232 RS
Wiring diagram: 1. RS232: CPU port DELTA DVP CPU port MT8000 RS232 9P D-SUB 8p mini DIN COM1 COM2 COM3 3 TX 4 TX 7 TX 4 RXD 2 RX 6 RX 8
39 EMERSON PLC EC20 Support Emerson PLC EC20 Series. (Modbus RTU Protocol) HMI Setting: Parameters Recommend Option Notes PLC type EMERSON PLC
4 AIBUS UDIAN Automation AI-501, AI-518, AI-519, AI-701, AI-702M, AI-704M, AI-706M, AI-719 http://www.yudian.us HMI Setting: Parameters Recommend O
40 W T ddd 0-255 9000-9255 W C ddd 0-199 9500-9699 DW C_Double ddd 200-255 9700-9811 DW D_Double dddd 0-7998 0000-7999 Wiring diagram: MT80
41 FATEK FB series FATEK FBs series, FB MC series, FB MA series need FB-DTBR converter. http://www.fatek.com/ HMI Setting: Parameters Recommend Opt
Wiring diagram: 1. RS232: FBs Port0 FBs MT8000 RS232 4P Mini-Din Male 42 COM1 COM2 COM3 3 TX 4 TX 7 TX 4RX 2 RX 6 RX 8 RX 3TX 4P Mini-D
43 Driver Version: Version Date Description of Changes V1.20 Jul/09/2009
44 Fuji NB Series PLC http://www.fujielectric.co.jp/fcs/eng/ HMI Setting: Parameters Recommend Option Notes PLC type Fuji NB Series Com por
Wiring diagram: MT8000 HMI FUJI NB Series COM1 [RS485]4w RJ45 8p connector 9P D-SUB 1 RX- 4 TX- 2 RX+ 3 TX+ 3 TX- 6 RX- 4 TX+ 5
46 GE Fanuc SNP-X GE Fanuc 90 & VersaMax series PLC http://www.ge.com HMI Setting: Parameters Recommend Option Notes PLC type GE Fanuc SNP-X
Wiring diagram: Memo:90 VersaMax series PLC of GE FANUC includes such series as 90-30, 90-70, VersaMax Micro, VersaMax Nano and VersaMax,etc., CPU of
48 CPU port(VersaMax series CPU001/002/005/E05) MT8000 RS232 9P D-SUB COM1 COM2 COM3 VersaMax series RS232 port 9P SUB-D Female 3 TX 4 TX 7 T
49 GE Fanuc Series 90-30 (Ethernet) GE 90-30 series, CPU model 374plus HMI Setting: Parameters Recommend Option Notes PLC type GE fanuc series 90
5 Device address: AI-518 Bit/Word Device Type Format Range Memo W 0 00H dd SV/STEP W 1 01H dd -1999~+9999 HIAL W 2 02H dd -1999~+9999 LoAL
Read Only, the rule is same as above W SC dd 1 ~ 17 Read Only, the rule is same as above W S dd 1 ~ 17 W R dddd 1 ~ 9999 W AI dddd 1 ~ 2
51 Ethernet: Direct connect (crossover cable) MT8000 Ethernet RJ45 Wire color Modbus TCP Device RJ45 1 TX+ White/Orange 3 RX+ 2 TX- Orange 6
52 HAN YOUNG Temperature Controller http://hynux.com/kor/ HMI Setting: Parameters Recommend Option Notes PLC type Heng Young Seires Com port RS
Heng Yuan Sensor EU sereis, EU5 series, EU10 series. http://www.hysensor.com.cn HMI Setting: 53 Parameters Recommend Option Notes PLC type Heng
54 Driver Version: Version Date Description of Changes V1.00 Dec/30/2008
55 HITACHI EHV HITACHI Web site: http://www.hitachi-ies.co.jp/english/products/plc/index.htm HMI Setting: Parameters recommend Option Notes PLC typ
Wiring diagram: Ethernet: MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 1 TX+ White/Orange 1 RX+ 1 8 2 TX- Orange 2 RX- RJ45 con
57 HITACHI H series (CPU port) Compatible PLCs Family Model HITACHI H series EH-150, Micro-EH, H20, H40, H64, H200, H250, H252, H300, H302, H700, H7
Device address: Device Bit/Word Format Range Memo Type B X hhh(h) hhh: 0~FFFF (h):0~F External Input-bit(X) B Y hhh(h) hhh: 0~FFFF (h):0~F
ON Low 9,600 bps Toggle-SwitchPHL Low PHL High ON High 38,400 bps OFF Low 4,800 bps Doesn’t support OFF High 19,200 bps Default 7 OFF (System
6 AI-701 Bit/Word Device Type Format Range Memo W 1 01H dd -9990~+30000 HIAL W 2 02H dd -9990~+30000 LoAL W 3 03H dd -9990~+30000 HdAL W 4 04
H series CPU RS232 port MT8000 PLC[232] HITACHI H series CPU RS232 15p D-SUB Male 9P D-SUB Male COM1 3 TX 3 RXD 2 RX 2 TXD 60 5 GND9SG8 CTS 4
61 HUST H4X HUST CNC Controller H4 Series http://www.hust.com.tw/ HMI Setting: Parameters Recommend Option Notes PLC type HUST H4X Com port RS-
62 B VM_bit ddddd(dd) 1 ~ 99999(31) Bit address (dd): 00~31。 Wiring diagram: MT8000 RS-232 / 9P D-SUB COM1 COM2 COM3 HUST CNC Controller RS232 P
63 IDEC IDEC Micro3, Micro3C, MicroSmart, OpenNet Controller series http://www.idec.com HMI Setting: Parameters Recommend Option Notes PLC type I
Wiring diagram: RS232: Micro3C, MicroSmart, OpenNet Controller CPU Ladder Port MT8000 RS232 CPU port 1 or port2 RS-232 64 8P mini DIN Male COM1 COM2
65 Driver Version: Version Date Description of Changes V1.20 Jun/19/2009
66 Intelligent Servo Intelligent Servo supports IDM640, IDM240. http://www.techsoftmotion.com HMI Setting: Parameters Recommend Option Notes PLC ty
67 JUSTFI Controller Justfi weighing instruments, Industrial Batching Controller supports XK31CB4, XK31CB6. http://www.justfi.com HMI Setting: Paramet
68 Wiring diagram: MT8000 RS232 9P D-SUB Female CB4(RS232) COM1 COM2 COM3 3 TX 4 TX 7 TX RD 2 RX 6 RX 8 RX TD 5 GND 5 GND 5 GND
69 KERNEL SISTEMI Kernel systemi DMX 30 http://www.kernel.modena.it/ HMI Setting: Parameters Recommend Option Notes PLC type Kernel sistemi C
Allen-Bradley CompactLogix / FlexLogix Allen-Bradley CompactLogix, FlexLogix CH0 DF1 http://www.ab.com HMI Setting: Parameters Recommend Option No
70 KEYENCE KV series KEYENCE KV series, KV10~80 http://www.keyence.com/ HMI Setting: Parameters Recommend Option Notes PLC type KEYENCE KV-16
71 If you use the Relay(bit) register, Please place zero behind address.For example, If you want to read Relay(bit)100, you just set the address as “1
72 KEYENCE KV-1000 http://www.keyence.com/ HMI Setting: Parameters Recommend Option Notes PLC type KEYENCE KV-1000 Com port RS232 RS232 Must
73 Precaution: If you use the Relay(bit) register, Please place zero behind address.For example, If you want to read Relay(bit)100, you just set the a
74 KEYENCE KV-5000 (Ethernet) http://www.keyence.com/ HMI Setting: Parameters Recommend Option Notes PLC type KEYENCE KV-5000 (Ethernet) Com port
Wiring diagram: Ethernet: MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 1 TX+ White/Orange 1 RX+ 1 8 2 TX- Orange 2 RX- RJ45
76 Korenix 6550 / 6520 http://www.korenix.com/ HMI Setting: Parameters Recommend Option Notes PLC type Korenix 6550/ 6520 Modbus protocol COM
Wiring diagram: Ethernet: MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 77 1 TX+ White/Orange 1 RX+ 1 8RJ45 2 TX- Orange 2 R
78 KOYO CLICK PLC Series KOYO CLICK PLC series http://www.automationdirect.com HMI Setting: Parameters Recommend Option Notes PLC type CLICK
Wiring diagram: KOYO CLICK PLC Com Port: RS-232: KOYO CLICK PLC EasyView MT8000 KOYO CLICK PLC RS-232 6 Pin RJ12 Jack 9P D-SUB COM1[RS232]
8 Device address: Bit/Word Device Type Format Range Memo B B_BOOL fffddd(dd) File no. ff: 3, 10~255 Element no. ddd: 0~255 Bit no. (dd): 0~15 Bit
80 KOYO DirectLogic KOYO DirectLogic series PLC DL05, DL06,DL105, DL205, DL305 and DL405 series http://www.automationdirect.com HMI Setting: Paramete
W Timer oooo 0 ~ 1000 W Counter oooo 0 ~ 1000 W V oooo 0 ~ 77777 V Memory Wiring diagram: 1. CPU unit: DL05/DL06/DL105/DL230/DL240/DL250/
4. CPU unit: DL430/DL440/DL450 CPU unit Port0 RS232 KOYO DirectLogic PLC MT8000 RS232 DL405 CPU RS232 Port0 9P D-SUB 15P D-SUB Female COM1 COM2 COM3 3
83 7. CPU unit: DL450 CPU unit Port3 RS422 MT8000 COM1[RS-485]4w 9P D-SUB KOYO DirectLogic PLC DL405 CPU RS422 Port3 25P D-SUB Female 1 RX- 13 TX- 2
84 KOYO DirectLogic Ethernet Module KOYO DirectLogic series, model H0-ECOM100 http://www.automationdirect.com HMI Setting: Parameters Recommend Opt
Wiring diagram: Ethernet port MT8000 Ethernet RJ45 Wire color Ethernet Hub or Switch RJ45 1 TX+ White/Orange 1 RX+ 2 TX- Orange 2 RX- 3
86 Lenze PLC Model No. : 9300/8200 series Pass-through 2102IB fieldbus module:RS485(LECOM B) http://www.lenze.de HMI Setting: Parameters Recommend
87 Driver Version: Version Date Description of Changes V1.10 Apr/17/2009
88 LS GLOFA Cnet LS GLOFA GM6/GM7 CPU port. G7L-CUEB / G6L-CUEB / G4L-CUEA / G3L-CUEA Cnet module. http://www.lgis.com/ HMI Setting: Parameters Recom
89 RS-232: Communication Module( G7L-CUEB / G6L-CUEB / G4L-CUEA / G3L-CUEA Cnet RS232 ) MT8000 RS232 9P D-SUB COM1 COM2 COM3 LG GLOFA GM RS232
2. In the Mapping frame, enter the File Number and Tag Name to be mapped. 3. Click on OK to configure the mapping. 9
90 LS GLOFA GM3 GM4 GM6 GM7 (Loader) LS GLOFA series GM3, GM4, GM6, GM7 CPU port http://www.lgis.com/ HMI Setting: Parameters Recommend Option Not
91 Driver Version: Version Date Description of Changes V1.20 Feb/11/2010 Modify the addressing
92 LS MASTER-K Cnet LS MASTER-K series: K80S, K200S, K300S, K1000S http://www.lgis.com/ HMI Setting: Parameters Recommend Option Notes PLC type L
93 Wiring diagram: MT8000 RS232 9P D-SUB COM1 COM2 COM3 CPU port Cnet I/F RS232 9P D-SUB Female 3 TX 4 TX 7 TX 4 RX 2 RX 6 RX 8 RX 7 TX
94 LS MASTER-K10S1 LS MASTER-K10S1 http://www.lgis.com/ HMI Setting: Parameters Recommend Option Notes PLC type LS MASTER-K10S1 Com port RS23
95 d: Decimal h: Hexadecimal Wiring diagram: MT8000 RS232 9P D-SUB COM1 COM2 COM3 CPU port RS232 9P D-SUB Female 3 TX 4 TX 7 TX 2 RX 2 RX
96 LS MASTER-K300S CPU LS MASTER-K series: K80S, K120S, K200S, K300S, K1000S http://www.lgis.com/ HMI Setting: Parameters Recommend Option Notes P
97 d: Decimal h: Hexadecimal Wiring diagram: MT8000 RS232 9P D-SUB COM1 COM2 COM3 CPU port RS232 9P D-SUB Female 3 TX 4 TX 7 TX 2 RX 2 R
98 LS XGB/XGT LS XGB/XGT Series http://www.lgis.com/ HMI Setting: Parameters Recommend Option Notes PLC type LS XGB/XGT Com port RS232 RS232/R
Wiring diagram: RS-232: 6pin female pinoutMT8000 RS232 XGB main unit 9P D-SUB RS232 6pin COM1 COM2 COM3 3 TX 4 TX 7 TX 2 RXD 2 RX 6 RX 8