244
*2 User define integer variable V000~V999, floating point variable F000~F999.
Wiring diagram:
MT8000 RS232
9P D-SUB
COM1 COM2 COM3
SMC3010 CN6
RS232
9 pin male D-sub
3 TX 4 TX 7 TX
3 RXD
2 RX 6 RX 8 RX
2 TXD
5 GND 5 GND 5 GND
5 GND
7 RTS
8 CTS