Memory Map protocol
Memory Map protocol is similar to IBM 3764R communication protocol. The MT8000 reserves
512 words of Data memory for use with this protocol. The MT8000 must update the values in
these words. The MT8000 uses the words to display data and control parts status on its screen.
When touch actions are taken, data is sent to the other once, and then update the memory in it. The
MT8000 is always responsible for updating the Data memory.
HMI Setting:
Parameters Recommend Option Notes
PLC type Memory Map
Com port RS232
RS232, RS485 4W, 2W RS232 default
Baud rate 115200 9600~115200
Parity bit Even Even, Odd, None
Data Bits 8
Stop Bits 1
Device address:
Bit/Word Device Type Format Range Memo
B
MB ddd(h) ddd:0~9999 (h): 0~F
W
MW ddd ddd:0~9999
The MB and MW are using same area to store data.
MW 0 = MB 000000 ~ MB 0000F
MW 1 = MB 000100 ~ MB 0001F
Wiring diagram:
RS-232:
MT8000 RS232
9P D-SUB
MT8000 RS232
9P D-SUB
2
RX 3 TX
3
TX 2 RX
5
GND 5GND
RS-485 2W:
MT8000 RS485
9P D-SUB
MT8000 RS485
9P D-SUB
1
RX- 1 RX-
2
RX+ 2 RX+
5
GND 5GND