HMI Setting:
33
Parameters Recommend Option Notes
PLC type Copley Controls
Com port RS232
Baud rate 9600 9600~115200
Parity bit None Even, Odd, None
Data Bits 8 8
Stop Bits 1 1
HMI Station No. 0
PLC Station No. 0 0-127
PLC Setting:
ASCII format
Device address:
Bit/Word Device Type Format Range Memo
Flash INT 16 hhh 0~FFF For Register is INT16 or U16
W
RAM INT 16 hhh 0~FFF For Register is INT16 or U16
W
Flash INT 32 hhh 0~FFF For Register is INT32 or U32
W
0~FFF For Register is INT32 or U32
W RAM INT 32 hhh
Wiring diagram:
Xenus, Xenus Micro, Accelnet
Xenus Micro Panel
RS-232 RJ11
MT8000 RS232
9P D-SUB
J7 cable connector
COM1 COM2 COM3
3 TX 4 TX 7 TX
2 RXD
2 RX 6 RX 8 RX
5 TXD
5 GND 5 GND 5 GND
3, 4 GND