Mitsubishi DD-6050 Manuel d'utilisateur Page 92

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 257
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 91
92
LS MASTER-K Cnet
LS MASTER-K series: K80S, K200S, K300S, K1000S
http://www.lgis.com/
HMI Setting:
Parameters Recommend Option Notes
PLC type LS MASTER-K Cnet
Com port RS232 RS232/RS485
Must match the PLC’s port setting.
Baud rate 38400 9600, 19200, 38400
Must match the PLC’s port setting.
Parity bit None Even, Odd, None
Must match the PLC’s port setting.
Data Bits 8 8
Must match the PLC’s port setting.
Stop Bits 1 1
Must match the PLC’s port setting.
HMI Station No. 0
Does not apply to this protocol.
PLC Station No. 0 0-31
Must match the PLC’s port setting.
Online Simulator YES
Extend address mode
PLC Setting:
Communication mode
38400, None, 8, 1
Device address:
Bit/Word
Device
Type
Format Range Memo
B P ddd(h) 0~255F I/O Relay (P)
B K ddd(h) 0~255F Keep Relay (K)
B M ddd(h) 0~255F Auxiliary Relay (M)
B L ddd(h) 0~255F Link Relay (L)
B F ddd(h) 0~255F Special Relay (F)
W TV ddd 0~255 Timer Present Value
W CV ddd 0~255 Counter Present Value
W D dddd 0~9999 Data Register (D)
d: Decimal h: Hexadecimal
Vue de la page 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 256 257

Commentaires sur ces manuels

Pas de commentaire