LS MASTER-K300S CPU
LS MASTER-K series: K80S, K120S, K200S, K300S, K1000S
http://www.lgis.com/
HMI Setting:
Parameters Recommend Option Notes
PLC type LG MASTER-K300S
Com port RS232 RS232/RS485
Must match the PLC’s port setting.
Baud rate 38400 9600, 19200, 38400
Must match the PLC’s port setting.
Parity bit None Even, Odd, None
Must match the PLC’s port setting.
Data Bits 8 8
Must match the PLC’s port setting.
Stop Bits 1 1
Must match the PLC’s port setting.
HMI Station No. 0
Does not apply to this protocol.
PLC Station No. 0 0-31
Must match the PLC’s port setting.
Online Simulator YES
Extend address mode
PLC Setting:
Communication
mode
38400, None, 8, 1
Device address:
Bit/Word
Device
Type
Format Range Memo
B P ddd(h) 0~255F I/O Relay (P)
B K ddd(h) 0~255F Keep Relay (K)
B M ddd(h) 0~255F Auxiliary Relay (M)
B L ddd(h) 0~255F Link Relay (L)
B F ddd(h) 0~255F Special Relay (F)
W TV ddd 0~255 Timer Present Value
W CV ddd 0~255 Counter Present Value
W D dddd 0~9999 Data Register (D)