Mitsubishi MOTION CONTROLLERS Q172DCPU Manuel d'instructions Page 264

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 316
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 263
APP - 19
A
PPENDICES
Table 2.2 Drive module error (100 to 1199) list (Continued)
Control mode of virtual servo axis
Error
class
Error
code
Positioning
Fixed-pitch feed
Speed
Speed switching
Constant-speed
JOG
Manual pulse generator
Synchronous encoder
Position follow-up
Error cause
Error
processing
Corrective action
• Q172DEX or encoder hardware
error.
• Check (replace) the Q172DEX
or encoder.
• Disconnected encoder cable
Immediate
input stop
• Check the encoder cable
1151
• A synchronous encoder set in the
system setting differs from a
synchronous encoder actually
connected.
Input from
synchro-
nous
encoder
does not
accept.
Set a synchronous encoder
actually connected in the
system setting.
1152
• Low voltage at Q172DEX. • Replace the battery.
Major
error
1153
• No battery or disconnected battery
at Q172DEX.
Operation
is
continued.
• Replace the battery or check
(replace) the Q172DEX.
Vue de la page 263
1 2 ... 259 260 261 262 263 264 265 266 267 268 269 ... 315 316

Commentaires sur ces manuels

Pas de commentaire