Vue de la page 211
8 - 27
8 OUTPUT MODULE
32767
V
t
t
Stroke amount
Lower stroke
limit value
1 cycle
(1 cam shaft revolution)
Cam pattern
Operation example
Stroke amount
Lower stroke
limit value
Output value
(Address)
Resolution-1
0
0
2) Feed cam mode .............With the lower stroke limit value (lower dead
point) as the operation start position,
positioning is executed by feeding one stroke
amount per cycle in a fixed direction.
Stroke amount
1 cycle
1 cycle 1 cycle
Current
value
Lower stroke limit value
(Lower dead point)
V
t
t
Cam pattern Operation example
Stroke
amount
1 cycle
Stroke
amount
1 cycle 1 cycle 1 cycle
Output value
(Address)
Resolution-1
Lower stroke
limit value
0
0