2.4.4 MELSEC-Q00, 01CPU: Connection to the Programming Port
Please confirm by parameter setup of MELSEC-Q00 and 01CPU "using a serial communication
function."
Item Setting
Station Number
0(DEC)
Data Bits
8bit(fixed)
Baud Rate
19200/38400/57600/115200 bps
Parity
Odd
Stop Bits
Use the same
settings as for
the MICRO/I.
1bit
Checksum Code Yes
2.4.5 MELSEC-Q02CPU: Connection to the Programming Port
Item Setting
Data Bits
8bit(fixed)
Baud Rate
9600/19200/38400/57600/115200 bps
Parity
Odd
Stop Bits
1bit