Chapter2 Connection to a PLC
2-142
(*3) Address selection rule is as follows.
Standard device address format of WindO/I-NV2
B
25525515
Example
MicroLogix1200 Address --- B
10:123/
WindO/I-NV2 Address --- B
1012305
3 digits File number
2 di
g
its Bit number
3 di
g
its Element number
Allen-Bradley device address format
B
255
:
255
/15
3 digits File number
2 di
g
its Bit number
3 di
g
its Element number
(*4)
Address selection rule is as follows.
Standard device address format of WindO/I-NV2
TEN
255255
Example
MicroLogix1200 Address --- T
12:123/EN
WindO/I-NV2 Address --- TEN
12123
3 di
its Element number
3 di
g
its File number
Allen-Bradley device address format
TEN
255
:
255
3 di
g
its Element number
3 di
g
its File number