5 SIEMENS
2-161
Chap.2
- The devices (V, I, Q, M, SM, S) which include a period in the address in S7-200 are written
without a period in MICRO/I.
- For example, V10.1 is written as V101 in MICRO/I.
- AC(Accumulator registers),L(Local memory) of PLC Devices can not use in MICRO/I.
The value of High speed counter which is a double word value is divided into two, and is
treated as WORD device in MICRO/I.
The higher word is written by adding 0 to the lowest digit of the address, the lower word is
written by adding 1 to the lowest digit of the address.
For example, the lower word of HC1 is written as HC11 in MICRO/I.
If you read in a double word value, The lowest digit of the address write 0 . For example,
HC2 is written as HC20 in MICRO/I.
(*1) The 1st figure is written with the number of octal number,
and the 2nd [ or more ] figure is written with the number of decimal.
(*2) Only even number can be specified.
(*3) The 1st figure is written with the number of binary number,
and the 2nd [ or more ] figure is written with the number of decimal.