Mitsubishi PLA-RP Manuel de service Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 86
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
2
1
TECHNICAL CHANGES
OFF
ON
4321
OFF
ON
4321
REVISED EDITION-A
PLA-RP3,4,5,6AA.UK PLA-RP3,4,5,6AA1.UK
1. Connectable outdoor unit has changed.
W Note: PLA-RP5AA.UK is connected to PUHZ-RP5VHA only.
PLA-RP5AA
1.UK can connect to PUHZ-RP5VHA, PUH-P5YGAA.UK, PUH-P5YGAA1.UK,
PU-P5YGAA.UK and PU-P5YGAA
1.UK.
PUHZ-RP3VHA
PUHZ-RP4VHA
PUHZ-RP5VHA
PUHZ-RP6VHA
OC294
R410A
OC297 (PLA-RP•AA.UK)
OC297 REVISED EDITION-A (PLA-RP•AA.UK, AA1.UK)
PUHZ-RP3VHA
PUHZ-RP4VHA
PUHZ-RP5VHA
PUHZ-RP6VHA
OC294
R410A
PUH-P3VGAA.UK
PUH-P3VGAA
1.UK
PUH-P3YGAA.UK
PUH-P3YGAA
1.UK
PUH-P4VGAA.UK
PUH-P4VGAA
1.UK
PUH-P4YGAA.UK
PUH-P4YGAA
1.UK
PUH-P5YGAA.UK W
PUH-P5YGAA
1.UK W
PUH-P6YGAA.UK
PUH-P6YGAA
1.UK
PU-P3VGAA.UK
PU-P3VGAA
1.UK
PU-P3YGAA.UK
PU-P3YGAA
1.UK
PU-P4VGAA.UK
PU-P4VGAA
1.UK
PU-P4YGAA.UK
PU-P4YGAA
1.UK
PU-P5YGAA.UK W
PU-P5YGAA
1.UK W
PU-P6YGAA.UK
PU-P6YGAA
1.UK
OC261 REVISED EDITION-A
R407C
PLA-RP5AA1.UK
2. Corresponding to the addition of connectable outdoor unit, the setting of SW2 (Capacity setting) on the indoor
controller board have also changed.
PLA-RP5AA.UK
PLA-RP5AA1.UK
REVISED EDITION-B
• PLA-RP1.6AA.UK, PLA-RP2AA.UK and PLA-RP2.5AA.UK are added in REVISED EDITION-B.
Revision:
12. PARTS LIST ” has been modified on page 82.
Service Ref.
Page
IncorrectRevise point Correct
82
FUNCTIONAL PARTS
No.14 CAPACITOR
S70 E02 255S70 E02 225
PLA-RP4AA.UK
PLA-RP4AA
1.UK