Mitsubishi PLA-RP Manuel de service Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 86
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input
Service Ref.
Power supply (phase, cycle, voltage)
Input
Running current
Starting current
External finish (Panel)
Heat exchanger
Fan
Fan (drive) o No.
Fan motor output kW
kW
kW
A
A
Airflow
(Low-Medium2-Medium1-High)
K / min (CFM)
External static pressure Pa (mmAq)
Booster heater kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D. mm (in.)
Dimensions
Indoor unit
W mm (in.)
D mm (in.)
H mm (in.)
Weight
kg (lbs.)
PLA-RP3AA.UK
PLA-RP3AA1.UK
Cooling Heating
26,300 31,400
7,700 9,200
3.42 3.48
PLA-RP3AA.UK
PLA-RP3AA
1.UK
Single phase, 50Hz, 220-230-240V
0.16 0.16
0.79 079
1.0 1.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct) o 1
0.070
15-16-18-20 (530-565-635-705)
0 (direct blow)
Remote controller & built-in
28-30-32-34
32 (1-1/4)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16) PANEL : 30 (1-3/16)
UNIT : 24 (53)
PUH-P3VGAA.UK / PUH-P3YGAA.UK
PUH-P3VGAA1.UK / PUH-P3YGAA1.UK
PANEL: 5 (11)
Outdoor unit Service Ref.
16
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input
Service Ref.
Power supply (phase, cycle, voltage)
Input
Running current
Starting current
External finish (Panel)
Heat exchanger
Fan
Fan (drive) o No.
Fan motor output kW
kW
kW
A
A
Airflow
(Low-Medium2-Medium1-High)
K / min (CFM)
External static pressure Pa (mmAq)
Booster heater kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D. mm (in.)
Dimensions
Indoor unit
W mm (in.)
D mm (in.)
H mm (in.)
Weight
kg (lbs.)
PLA-RP2.5AA.UK
Cooling Heating
22,900 24,900
6,700 7,300
2.57 2.40
PLA-RP2.5AA.UK
Single phase, 50Hz, 220-230-240V
0.16
0.79
1.0
0.16
0.79
1.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct) o 1
0.070
14-15-16-18(495-530-565-635)
0 (direct blow)
Remote controller & built-in
28-29-31-33
32 (1-1/4)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16) PANEL : 30 (1-3/16)
UNIT : 24 (53)
PUH-P2.5VGAA.UK / PUH-P2.5YGAA.UK
PUH-P2.5VGAA
1.UK / PUH-P2.5YGAA1.UK
PANEL: 5 (11)
Outdoor unit Service Ref.
NOTE: 1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)
Heating Indoor : D.B. 20: (68˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor Outdoor
Cooling
Upper limit
D.B. 35˚C, W.B. 22.5˚C
D.B. 46˚C
Lower limit
D.B. 19˚C, W.B. 15˚C D.B. -5˚C
Heating
Upper limit
D.B. 28˚C
D.B. 24˚C, W.B. 18˚C
Lower limit
D.B. 17˚C
D.B. -11˚C, W.B. -12˚C
4. Above data based on indicated voltage
Indoor unit Single phase 230V 50Hz
Single phase 230V 50Hz / 3 phase 400V 50HzOutdoor unit
3. Guaranteed voltage
198~264V, 50Hz
5. Refer to the service manual of outdoor unit for tha outdoor
unit's specifications.
OC297-E-1.qxp 05.5.6 5:29 PM Page 16