TECHNICAL & SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES······························2
2.
COMBINATION OF INDOOR AND OUTDOOR UNITS
···3
3. SAFETY PRECAUTION·······························4
4. PART NAMES AND FUNCTIONS ···············8
5. SPECIFICATIONS ······································11
6. DATA ··························································21
7. OUTLINES AND DIMENSIONS ·················60
8. WIRING DIAGRAM ····································61
9. REFRIGERANT SYSTEM DIAGRAM········62
10. TROUBLESHOOTING ·······························63
11. DISASSEMBLY PROCEDURE ··················74
12. PARTS LIST ···············································77
13. OPTIONAL PARTS ····································84
Indoor unit
[Model names] [Service Ref.]
PLA-RP1.6AA PLA-RP1.6AA.UK
PLA-RP2AA PLA-RP2AA.UK
PLA-RP2.5AA PLA-RP2.5AA.UK
PLA-RP3AA PLA-RP3AA.UK
PLA-RP3AA1.UK
PLA-RP4AA PLA-RP4AA.UK
PLA-RP4AA1.UK
PLA-RP5AA PLA-RP5AA.UK
PLA-RP5AA1.UK
PLA-RP6AA PLA-RP6AA.UK
PLA-RP6AA1.UK
No.OC297
REVISED EDITION-E
INDOOR UNIT
WIRED REMOTE
CONTROLLER
WIRELESS REMOTE
CONTROLLER
ON/OFF TEMP
MODEL SELECT
NOT AVAILABLE
CHECK
TEST RUN
˚C
AMPM
AMPM
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN
FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY
DEFROST
TEMP.
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS
Revision:
• “12. PARTS LIST” has been
modified.
• Please void OC297 REVISED
EDITION-D.
Note:
This manual does not cover
outdoor units. When serving
them, please refer to the service
manual No.OC294 REVISED
EDITION-D, OC261REVISED
EDITION-D and this manual in a
set.
Model name
indication
OC297-E-1.qxp 05.5.6 5:29 PM Page 1
Vue de la page 0
1 2 3 4 5 6 ... 85 86

Résumé du contenu

Page 1 - TEST RUN

TECHNICAL & SERVICE MANUALCONTENTS1. TECHNICAL CHANGES······························22. COMBINATION OF INDOOR AND OUTDOOR UNITS···33. SAFETY PRECA

Page 2 - TECHNICAL CHANGES

10ON/OFF TEMPFANVANETEST RUNAUTO STOPAUTO STARThminLOUVERMODECHECKRESETSET CLOCKMODEL SELECTNOT AVAILABLECHECKTEST RUN˚CAMPMAMPMVANE CONTROL buttonU

Page 3

11SPECIFICATIONS5Heat pump type (1)Service Ref.ItemFunctionCapacityBtu/hWTotal inputService Ref.Power supply (phase, cycle,voltage)InputRunning curren

Page 4 - SAFETY PRECAUTION

12Service Ref.ItemFunctionCapacityBtu/hWTotal inputService Ref.Power supply (phase, cycle, voltage)InputRunning current AStarting current AExterna

Page 5 - [3] Service tools

13Service Ref.ItemFunctionCapacityBtu/hWWPUHZ-RP4VHAPUHZ-RP4VHA1Total inputService Ref.Power supply (phase, cycle, voltage)InputRunning current ASta

Page 6 - [1] Cautions for service

14Cooling Heating47,800 54,60014,000 (6,200~15,300)14,000 (5,500~15,300)16,000 (6,200~18,000)16,000 (5,000~18,000)4.99 4.91PLA-RP6AA.UKPLA-RP6AA1.UKS

Page 7 - Gravimeter

15Heat pump type (2)Service Ref.ItemFunctionCapacityBtu/hWkWkWTotal inputService Ref.Power supply (phase, cycle, voltage)InputRunning current AStart

Page 8 - PART NAMES AND FUNCTIONS

Service Ref.ItemFunctionCapacityBtu/hWTotal inputService Ref.Power supply (phase, cycle, voltage)InputRunning currentStarting currentExternal finish (

Page 9 - SET TEMPERATURE display

17NOTE: 1. Rating conditions (ISO T1)Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)Heating

Page 10 - ON/OFF TEMP

18NOTE: 1. Rating conditions (ISO T1)Cooling : Indoor: D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor: D.B. 35: (95˚F) W.B. 24: (75˚F)Heating : I

Page 11 - SPECIFICATIONS

19Cooling only type (3)NOTE: 1. Rating conditions (ISO T1)Cooling : Indoor: D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor : D.B. 35: (95˚F) W.B. 2

Page 12

21TECHNICAL CHANGESOFFON4321OFFON4321REVISED EDITION-APLA-RP3,4,5,6AA.UK PLA-RP3,4,5,6AA1.UK1. Connectable outdoor unit has changed. W Note: PLA-RP5AA

Page 13

20NOTE: 1. Rating conditions (ISO T1)Cooling : Indoor: D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)Refrigerant

Page 14

21DATA66-1. PERFORMANCE DATA6-1-1. COOLING CAPACITY (1) PLA-RP1.6AA.UK / PUHZ-RP1.6VHA(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.

Page 15 - 1.UK / PUH-P2YGAA1.UK

22COOLING CAPACITY (2) PLA-RP1.6AA.UK / PUHZ-RP1.6VHA(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: S

Page 16 - 1.UK / PUH-P2.5YGAA1.UK

23COOLING CAPACITY (3) PLA-RP2AA.UK / PUHZ-RP2VHA(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensi

Page 17 - 1.UK / PUH-P4YGAA1.UK

24COOLING CAPACITY (4) PLA-RP2AA.UK / PUHZ-RP2VHA(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensi

Page 18

25COOLING CAPACITY (5)(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensible heat factor2020202222222

Page 19 - 1.UK / PU-P2YGAA1.UK

26COOLING CAPACITY (6)(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensible heat factor2020202222222

Page 20 - 1.UK / PU-P4YGAA1.UK

27COOLING CAPACITY (7)(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensible heat factor2020202222222

Page 21 - 6-1-1. COOLING CAPACITY (1)

28COOLING CAPACITY (8)(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensible heat factor2020202222222

Page 22 - COOLING CAPACITY (2)

29COOLING CAPACITY (9) PLA-RP4AA.UK PLA-RP4AA1.UK / PUHZ-RP4VHAPUHZ-RP4VHA1(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power c

Page 23 - PLA-RP2AA.UK / PUHZ-RP2VHA

3COMBINATION OF INDOOR AND OUTDOOR UNITS2Heat pump typeOutdoor unit [OC261 REVISED EDITION-B]PUH-PHeat pump withoutelectric heater6YGAA.UKYGAA1.UK————

Page 24

30COOLING CAPACITY (10) PLA-RP4AA.UK PLA-RP4AA1.UK / PUHZ-RP4VHAPUHZ-RP4VHA1(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power

Page 25 - PUHZ-RP2.5VHA

31COOLING CAPACITY (11) PLA-RP5AA.UK PLA-RP5AA1.UK / PUHZ-RP5VHAPUHZ-RP5VHA1(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power

Page 26

32COOLING CAPACITY (12) PLA-RP5AA.UK PLA-RP5AA1.UK / PUHZ-RP5VHAPUHZ-RP5VHA1(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power

Page 27 - PUHZ-RP3VHA

33COOLING CAPACITY (13) PLA-RP6AA.UK PLA-RP6AA1.UK / PUHZ-RP6VHAPUHZ-RP6VHA1(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power

Page 28

34COOLING CAPACITY (14) PLA-RP6AA.UK PLA-RP6AA1.UK / PUHZ-RP6VHAPUHZ-RP6VHA1(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power

Page 29 - PUHZ-RP4VHA

35COOLING CAPACITY (15) PLA-RP1.6AA.UK / PUH-P1.6VGAA.UKPUH-P1.6VGAA1.UKPU-P1.6VGAA.UKPU-P1.6VGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensible heat

Page 30

36COOLING CAPACITY (16)PLA-RP1.6AA.UK / PUH-P1.6VGAA.UKPUH-P1.6VGAA1.UKPU-P1.6VGAA.UKPU-P1.6VGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensible heat

Page 31 - PUHZ-RP5VHA

37COOLING CAPACITY (17)PLA-RP2AA.UK / PUH-P2VGAA.UKPUH-P2VGAA1.UKPU-P2VGAA.UKPU-P2VGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity

Page 32

38COOLING CAPACITY (18)PLA-RP2AA.UK / PUH-P2VGAA.UKPUH-P2VGAA1.UKPU-P2VGAA.UKPU-P2VGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity

Page 33 - PUHZ-RP6VHA

39COOLING CAPACITY (19) PLA-RP2.5AA.UK / PUH-P2.5VGAA.UKPUH-P2.5VGAA1.UKPU-P2.5VGAA.UKPU-P2.5VGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensible heat

Page 34

43SAFETY PRECAUTION[2] Refrigerant recharging(1) Refrigerant recharging process1Direct charging from the cylinder.·R407C cylinder are available on th

Page 35 - COOLING CAPACITY (15)

40COOLING CAPACITY (20) PLA-RP2.5AA.UK / PUH-P2.5VGAA.UKPUH-P2.5VGAA1.UKPU-P2.5VGAA.UKPU-P2.5VGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensible heat

Page 36 - COOLING CAPACITY (16)

41(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensible heat factor202020222222242424242626262627272

Page 37 - COOLING CAPACITY (17)

42COOLING CAPACITY (22)(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensible heat factor202020222222

Page 38 - COOLING CAPACITY (18)

43COOLING CAPACITY (23)(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensible heat factor202020222222

Page 39 - COOLING CAPACITY (19)

44COOLING CAPACITY (24)(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacity (W)P.C.: Power consumption (kW) SHF: Sensible heat factor202020222222

Page 40 - COOLING CAPACITY (20)

45COOLING CAPACITY (25) PLA-RP5AA1.UK / PUH-P5YGAA.UKPUH-P5YGAA1.UKPU-P5YGAA.UKPU-P5YGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacit

Page 41 - COOLING CAPACITY (21)

46COOLING CAPACITY (26) PLA-RP5AA1.UK / PUH-P5YGAA.UKPUH-P5YGAA1.UKPU-P5YGAA.UKPU-P5YGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensible heat capacit

Page 42 - COOLING CAPACITY (22)

47COOLING CAPACITY (27) PLA-RP6AA.UK PLA-RP6AA1.UK / PUH-P6YGAA.UKPUH-P6YGAA1.UKPU-P6YGAA.UKPU-P6YGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensibl

Page 43 - COOLING CAPACITY (23)

48COOLING CAPACITY (28) PLA-RP6AA.UK PLA-RP6AA1.UK / PUH-P6YGAA.UKPUH-P6YGAA1.UKPU-P6YGAA.UKPU-P6YGAA1.UK(230V)NOTE:CA : Capacity (W) SHC: Sensib

Page 44 - COOLING CAPACITY (24)

496-1-2. HEATING CAPACITYNOTE: CA: Capacity (W)P.C.: Power consumption (kW)Outdoor intake air W.B. (:)-10 -5 0 5 10 15CAIndoorintake areD.B. (˚C)P.C.

Page 45 - COOLING CAPACITY (25)

5[3] Service toolsUse the below service tools as exclusive tools for R407C refrigerant.No. Tool name Specifications1 Gauge manifold ·Only for R407C.·U

Page 46 - COOLING CAPACITY (26)

50Heating performance curve(50Hz)1.41.21.01520252520150.80.60.41.41.21.00.80.60.4-12 -10 -5 0 5 10 15INDOORD.B.(°C)INDOORD.B.(°C)OUTDOOR W.B.(°C)CAPAC

Page 47 - COOLING CAPACITY (27)

Cooling capacity correction factorsService Ref.Refrigerant piping length(one way)5m 10m 20m 30m 40m 50m1.001.001.001.001.001.001.000.9930.9930.9890.98

Page 48 - COOLING CAPACITY (28)

52TotalElectrical circuitRefrigerant circuitIndoor sideOutdoorsideService Ref.SHFBFWkWModeCapacityInputPLA-RP1.6AA.UK PLA-RP2AA.UK PLA-RP2.5AA.UKPLA-R

Page 49 - 1.UK PUH-P•YGAA1.UK

53TotalElectrical circuitRefrigerant circuitIndoor sideOutdoorsideService Ref.SHFBFWkWModeCapacityInputPLA-RP3AA.UKPLA-RP3AA1.UKPLA-RP4AA.UKPLA-RP4AA1

Page 50 - OUTDOOR W.B.(°C)

54TotalElectrical circuitRefrigerant circuitIndoor sideOutdoorsideService Ref.SHFBFWkWModeCapacityInputPLA-RP1.6AA.UKPLA-RP2AA.UKPLA-RP2.5AA.UKPLA-RP1

Page 51 - PU-P•VGAA1.UK PU-P•YGAA1.UK

55TotalElectrical circuitRefrigerant circuitIndoor sideOutdoorsideService Ref.SHFBFWkWModeCapacityInputPLA-RP3AA.UKPLA-RP3AA1.UKPLA-RP4AA.UKPLA-RP4AA1

Page 52 - 6-4. STANDARD OPERATION DATA

56TotalElectrical circuitRefrigerant circuitIndoor sideOutdoorsideService Ref.SHFBFWkWVAVAMPaMPa°C°C°Cm°C°C°C°C°CModeCapacityInputIndoor unit Service

Page 53

57TotalElectrical circuitRefrigerant circuitIndoor sideOutdoorsideService Ref.SHFBFWkWVAVAMPaMPa°C°C°Cm°C°C°C°C°CModeCapacityInputIndoor unit Service

Page 54 - Heat pump type (2)

58PLA-RP1.6AA.UK PLA-RP2AA.UKPLA-RP2.5AA.UKNOTCH SPL(dB) LINEHighMedium1Medium2LowHighMedium1Medium2Low31292827NOTCH SPL(dB) LINE333129289080706050403

Page 55

59UNIT1.5mMICROPHONECEILINGPLA-RP5AA.UKPLA-RP5AA1.UKPLA-RP6AA.UKPLA-RP6AA1.UKNOTCH SPL(dB) LINE45434037NOTCH SPL(dB) LINE4543403790807060504030201063

Page 56 - Cooling only type (3)

6Cautions for units utilising refrigerant R410ACAUTIONS RELATED TO NEW REFRIGERANTUse new refrigerant pipes.Make sure that the inside and outside of r

Page 57

607OUTLINES AND DIMENSIONSPLA-RP2.5,3AAPLA-RP1.6,2AAModelsPLA-RP4,5,6AARefrigerant pipe(9.52mm dia.)flared connection 3/8FFOR PUHZ-RP typeRefrigerant

Page 58 - BAND CENTER FREQUENCIES, Hz

61WIRING DIAGRAM8[Servicing]Fasten terminal of the terminal board "TB4" equips lock system.To remove the fastened terminal, pull it while pr

Page 59 - PLA-RP6AA1.UK

629REFRIGERANT SYSTEM DIAGRAMThermistor TH2Pipe temperature (Liquid)Distributorwith strainer(#50)Thermistor TH5(Cond./Eva. temperature)Thermistor TH1(

Page 60 - OUTLINES AND DIMENSIONS

63TROUBLESHOOTING10<Error code display by self-diagnosis and actions to be taken for service (summary)>Present and past error codes are logged a

Page 61 - WIRING DIAGRAM

6410-2. SELF-DIAGNOSIS ACTION TABLENote: Refer to the manual of outdoor unit for the details of display such as F, U, and other E.Error CodeMeaning of

Page 62 - REFRIGERANT SYSTEM DIAGRAM

65123456ONOFF123456ONOFF123456ONOFF123456ONOFFA-Control Service Tool SW2 settingTemperature display of indoor liquid pipeIndoor 1Temperature displ

Page 63 - TROUBLESHOOTING

66Error CodeMeaning of error code and detection method CaseJudgment and actionP9Abnormality of pipe temperature ther-mistor / Condenser-Evaporator (TH

Page 64

6710-3. TROUBLESHOOTING BY INFERIOR PHENOMENANote: Refer to the manual of outdoor unit for the detail of remote controller.(3)Upward/downward vane per

Page 65

6810-4. EMERGENCY OPERATION 10-4-1. When wireless remote controller troubles or its battery is exhausted1. Emergency operation is available in such a

Page 66

6910-5. HOW TO CHECK THE PARTSPLA-RP1.6AA.UKPLA-RP2AA.UKPLA-RP2.5AA.UKPLA-RP3AA.UK PLA-RP3AA1.UKPLA-RP4AA.UK PLA-RP4AA1.UKPLA-RP5AA.UK PLA-RP5AA1.U

Page 67

7GravimeterUnit[3] Service toolsUse the below service tools as exclusive tools for R410A refrigerant.No. Specifications1 Gauge manifold ·Only for R410

Page 68 - 10-4. EMERGENCY OPERATION

7001020304050-20 -10 0 10 20 30 40 50< Thermistor for lower temperature >Temperature (:)Resistance (K")<Thermistor Characteristic graph&

Page 69 - Fan motor

10-6. TEST POINT DIAGRAM10-6-1. Power boardPLA-RP1.6AA.UKPLA-RP2AA.UKPLA-RP2.5AA.UKPLA-RP3AA.UK PLA-RP3AA1.UKPLA-RP4AA.UK PLA-RP4AA1.UKPLA-RP5AA.UK

Page 70 - 0=6.0k' ±5%

10-6-2. Controller boardPLA-RP1.6AA.UKPLA-RP2AA.UKPLA-RP2.5AA.UKPLA-RP3AA.UK PLA-RP3AA1.UKPLA-RP4AA.UK PLA-RP4AA1.UKPLA-RP5AA.UK PLA-RP5AA1.UKPLA-R

Page 71 - 10-6. TEST POINT DIAGRAM

7310-7. FUNCTIONS OF JUMPER WIREEach function is controlled by the jumper wire on control p.c. board. For service parts, J11- J15 and J21-J24, DIP swi

Page 72

74DISASSEMBLY PROCEDURE11OPERATING PROCEDUREPHOTOS & ILLUSTRATIONS1. Removing the air intake grille(1) Slide the knob of air intake grille toward

Page 73

75OPERATING PROCEDUREPHOTOS & ILLUSTRATIONS6. Removing the pipe temperature thermistorand condenser evaporator temperature thermistor(1) Remove th

Page 74 - DISASSEMBLY PROCEDURE11

76OPERATING PROCEDUREPHOTOS & ILLUSTRATIONS10. Removing the heat exchanger(1) Remove the panel. (See photo 6)(2) Remove the fan guard. (See photo

Page 75 - PHOTOS & ILLUSTRATIONS

7712 PARTS LISTNo. Parts No.Parts NameSpecifi-cationQ'ty / setWIRELESSWIREDRemarks(Drawing No.)WiringDiagramSymbolRecom-mendedQ'tyUnit Amoun

Page 76

78No.Parts No.Parts NameQ'ty / setPLA-RP1.6AA.UKPLA-RP2AA.UKPLA-RP2.5AA.UKWiringDiagramSymbolRecom-mendedQ'tyUnit AmountPrice123456789101112

Page 77 - 12 PARTS LIST

79No.Parts No.Parts NameQ'ty / setPLA-RP3AA.UKPLA-RP3AA1.UKPLA-RP4AA.UKPLA-RP4AA1.UKWiringDiagramSymbolRecom-mendedQ'tyUnit AmountPrice12345

Page 78

8● Operation buttonsPAR-20MAAON/OFF CENTRALLY CONTROLLEDERROR CODECLOCKON OFF˚CCHECKCHECK MODEFILTERTEST RUNFUNCTION˚C1Hr.NOT AVAILABLESTAND BY DEFROS

Page 79

80No.Parts No.Parts NameWiringDiagramSymbolRecom-mendedQ'tyUnit AmountPrice12345678910111213141516BASELEGDRUM 1 ASSYLEGTURBO FANSPL WASHERHEAT EX

Page 80

81No. Parts No. Parts NameWiringDiagramSymbolRecom-mendedQ'tyUnit AmountPrice123456789101112131415161718DRAIN PANDRAIN SOCKETDRAIN PUMPDRAIN SENS

Page 81 - No. Parts No. Parts Name

82No. Parts No. Parts NameWiringDiagramSymbolRecom-mendedQ'tyUnit AmountPrice123456789101112131415161718DRAIN PANDRAIN PANDRAIN SOCKETDRAIN PUMPD

Page 82

83No. Parts No. Parts NameWiringDiagramSymbolRecom-mendedQ'tyUnit AmountPrice123456789101112131415161718DRAIN PANDRAIN SOCKETDRAIN PUMPDRAIN SENS

Page 83

84OPTIONAL PARTS1313-1. PROGRAM TIMER13-1-1. Names and functions<PAC-YT32PTA>Part No. PAC-YT32PTAA SET/MONITOR DISPLAY:When SET is displayed, cl

Page 84 - OPTIONAL PARTS

85PAC-SG03TM-EPLA-RP1.6,2,2.5,3,4,5,6AA.UKPLA-RP3,4,5,6AA1.UK13-2. MULTI-FUNCTIONAL CASEMENTPart No.Applied Service Ref.PAC-SG01KFPLA-RP1.6,2,2.5,3,4,

Page 85

cCopyright 2003 MITSUBISHI ELECTRIC ENGINEERING CO., LTD.Distributed in May 2005 No. OC297 REVISED EDITION-E PDF 8Distributed in Feb. 2005 No. OC297 R