NOTE: 1. Rating conditions (ISO T1)
Cooling : Indoor: D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C
Lower limit D.B. 19˚C, W.B. 15˚C D.B. -5˚C
4. Above data based on indicated voltage
Indoor unit Single phase 230V 50Hz
Outdoor unit Single phase 230V 50Hz, 3 phase 400V 50Hz
3. Guaranteed voltage
198~264V, 50Hz
5. Refer to the service manual of outdoor unit for tha outdoor
unit's specifications.
Weight kg (lbs.)
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input kW
Service Ref.
Power supply (phase, cycle, voltage)
Input kW
Running current A
Starting current A
External finish (Panel)
Heat exchanger
Fan
Fan (drive) o No.
Fan motor output kW
Airflow
(Low-Medium2-Medium1-High)
K / min (CFM)
External static pressure Pa (mmAq)
Booster heater kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D. mm (in.)
Dimensions
Indoor unit
W mm (in.)
D mm (in.)
H mm (in.)
PLA-RP5AA
1.UK
PLA-RP6AA.UK
PLA-RP6AA1.UK
Cooling
45,400 48,500
13,300 14,200
5.09 5.90
PLA-RP5AA
1.UK
PLA-RP6AA1.UK
PLA-RP6AA.UK
Single phase, 50Hz, 220-230-240V
0.33 0.33
1.64 1.64
2.0 2.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct) o 1
0.120
22-25-28-30 (775-880-990-1,060)
0 (direct blow)
Remote controller & built-in
37-40-43-45
32 (1-1/4)
PU-P5YGAA.UK
PU-P5YGAA1.UK
PU-P6YGAA.UK
PU-P6YGAA1.UK
Outdoor unit Service Ref.
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 298 (11-3/4), PANEL : 30 (1-3/16)
UNIT : 32 (71), PANEL : 5 (11)
Weight kg (lbs.)
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input kW
Service Ref.
Power supply (phase, cycle, voltage)
Input kW
Running current A
Starting current A
External finish (Panel)
Heat exchanger
Fan
Fan (drive) o No.
Fan motor output kW
Airflow
(Low-Medium2-Medium1-High)
K / min (CFM)
External static pressure Pa (mmAq)
Booster heater kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D. mm (in.)
Dimensions
Indoor unit
W mm (in.)
D mm (in.)
H mm (in.)
Cooling
26,300 32,800
7,700 9,600
3.42 3.68
PLA-RP3AA1.UK PLA-RP4AA1.UK
PLA-RP3AA.UK PLA-RP4AA.UK
Single phase, 50Hz, 220-230-240V
0.16 0.25
0.79 1.25
1.0 2.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct) o 1
0.070 0.120
15-16-18-20 (530-565-635-705) 20-23-26-28 (705-810-920-990)
0 (direct blow)
Remote controller & built-in
28-30-32-34 33-36-39-41
32 (1-1/4)
PU-P3VGAA.UK / PU-P3YGAA.UK
PU-P3VGAA1.UK / PU-P3YGAA1.UK
PU-P4VGAA.UK / PU-P4YGAA.UK
PU-P4VGAA1.UK / PU-P4YGAA1.UK
PLA-RP3AA1.UK
PLA-RP3AA.UK
PLA-RP4AA1.UK
PLA-RP4AA.UK
Outdoor unit Service Ref.
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16), PANEL : 30 (1-3/16)
UNIT : 24 (53), PANEL : 5 (11)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 298 (11-3/4), PANEL : 30 (1-3/16)
UNIT : 30 (66), PANEL : 5 (11)