Cooling only type (3)
NOTE: 1. Rating conditions (ISO T1)
Cooling : Indoor: D.B. 27: (80˚F) W.B. 19: (66˚F) Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C
Lower limit D.B. 19˚C, W.B. 15˚C D.B. -5˚C
4. Above data based on indicated voltage
Indoor unit Single phase 230V 50Hz
Outdoor unit Single phase 230V 50Hz, 3 phase 400V 50Hz
3. Guaranteed voltage
198~264V, 50Hz
5. Refer to the service manual of outdoor unit for tha outdoor
unit's specifications.
Weight kg (lbs.)
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input kW
Service Ref.
Power supply (phase, cycle, voltage)
Input kW
Running current A
Starting current A
External finish (Panel)
Heat exchanger
Fan
Fan (drive) o No.
Fan motor output kW
Airflow
(Low-Medium2-Medium1-High)
K / min (CFM)
External static pressure Pa (mmAq)
Booster heater kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D. mm (in.)
Dimensions
Indoor unit
W mm (in.)
D mm (in.)
H mm (in.)
PLA-RP2.5AA.UK
Cooling
22,900
6,700
2.57
PLA-RP2.5AA.UK
Single phase, 50Hz, 220-230-240V
0.16
0.79
1.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct) o 1
0.070
14-15-16-18 (495-530-565-635)
0 (direct blow)
Remote controller & built-in
28-29-31-33
32 (1-1/4)
Outdoor unit Service Ref.
PU-P2.5VGAA.UK / PU-P2.5YGAA.UK
PU-P2.5VGAA
1.UK / PU-P2.5YGAA1.UK
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16), PANEL : 30 (1-3/16)
UNIT : 24 (53), PANEL : 5 (11)
Weight kg (lbs.)
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input kW
Service Ref.
Power supply (phase, cycle, voltage)
Input kW
Running current A
Starting current A
External finish (Panel)
Heat exchanger
Fan
Fan (drive) o No.
Fan motor output kW
Airflow
(Low-Medium2-Medium1-High)
K / min (CFM)
External static pressure Pa (mmAq)
Booster heater kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D. mm (in.)
Dimensions
Indoor unit
W mm (in.)
D mm (in.)
H mm (in.)
Cooling
15,400 19,100
4,500 5,600
1.72 2.53
PLA-RP1.6AA.UK PLA-RP2AA.UK
Single phase, 50Hz, 220-230-240V
0.16 0.16
0.79 0.79
1.0 1.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct) o 1
0.070 0.070
11-12-13-14 (390-425-460-495) 14-15-16-18 (495-530-565-635)
0 (direct blow)
Remote controller & built-in
27-28-29-31 28-29-31-33
32 (1-1/4)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16), PANEL : 30 (1-3/16)
UNIT : 24 (53), PANEL : 5 (11)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16), PANEL : 30 (1-3/16)
UNIT : 24 (53), PANEL : 5 (11)
PU-P1.6VGAA.UK / PU-P1.6YGAA.UK
PU-P1.6VGAA1.UK / PU-P1.6YGAA1.UK
PU-P2VGAA.UK / PU-P2YGAA.UK
PU-P2VGAA1.UK / PU-P2YGAA1.UK
PLA-RP1.6AA.UK PLA-RP2AA.UK
Outdoor unit Service Ref.
OC297-E-1.qxp 05.5.6 5:29 PM Page 19
Vue de la page 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 85 86

Commentaires sur ces manuels

Pas de commentaire