MITSUBISHI (6/29) AA084SB01--T2_02_00
VCC-dip conditions:
1) When 2.6 V
≤ VCC < 3.0 V, td ≤ 10 ms
2) When VCC < 2.6 V
VCC-dip conditions should also follow the power and signals sequence.
td
2.6 V
3.0 V
VCC
*2) VCC = +3.3 V , f
H
=37.9 kHz, f
V
=60 Hz, f
CLK
= 40 MHz
Display image at typical power supply current value is 256-gray-bar pattern (8 bit), 600 line
mode.
*3) Fuse
Parameter Fuse Type Name Supplier Remark
VCC FCC16162AB Kamaya Electric Co., Ltd. *)
*) The power supply capacity should be designed to be more than the fusing current.
(2) Backlight
ITEM SYMBOL MIN. TYP. MAX. UNIT Remarks
-- (30) 36.6 V IF = 60mA, Ta = 25°C, *2)
-- -- 37.9 V IF = 60mA, Ta = 0°C
LED Voltage VF
-- -- 39.1 V
IF = 60mA, Ta = −20°C
LED Current IF -- 60 70 mA Ta = 25°C, *1), *3)
LED Life Time LT 80,000 100,000 -- h
IF = 60 mA, Ta = 25°C
*4), *5), Continuous operation
[Note]
*1) Constant Current Drive
*2) The Voltage deviation between strings: |V
f1
– V
f2
| ≤ 2 V
*3) LED Current measurement method
C1
A1
C2
A2
LCD
Module
A
Power
Supply
A
Power
Supply
*4) LED life time is defined as the time when the brightness becomes 50% of the initial value.
*5) The life time of the backlight depends on the ambient temperature. The life time will decrease
under high temperature.