Mitsubishi PEN-2 Manuel d'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
MITSUBISHI (8/29) AA084SB01--T2_02_00
5. INTERFACE PIN CONNECTION
(1) CN 1(Interface Signal)
Used connector: 20186-020E-11F(I-PEX) or FI-SEB20P-HFE (JAE)
Corresponding connector: 20197-20U-F(I-PEX) or FI-S20S [for discrete Wire],
FI-SE20ME [for FPC] (JAE)
Function(ISP 6 bit compatibility mode)
Pin
No.
Symbol
6 bit input 8 bit input
Function(ISP 8 bit
compatibility mode)
1 VCC
+3.3 V Power supply
2 VCC
+3.3 V Power supply
3 GND
GND
4 GND
GND
5
Link 0
R0, R1, R2, R3, R4, R5, G0 R2, R3, R4, R5, R6, R7, G2
R0, R1, R2, R3, R4, R5, G0
6 Link 0+ R0, R1, R2, R3, R4, R5, G0 R2, R3, R4, R5, R6, R7, G2 R0, R1, R2, R3, R4, R5, G0
7 GND
GND
8
Link 1
G1, G2, G3, G4, G5, B0, B1 G3, G4, G5, G6, G7, B2, B3
G1, G2, G3, G4, G5, B0, B1
9 Link 1+ G1, G2, G3, G4, G5, B0, B1 G3, G4, G5, G6, G7, B2, B3 G1, G2, G3, G4, G5, B0, B1
10 GND
GND
11
Link 2
B2, B3, B4, B5, DENA B4, B5, B6, B7, DENA
B2, B3, B4, B5, DENA
12 Link 2+ B2, B3, B4, B5, DENA B4, B5, B6, B7, DENA B2, B3, B4, B5, DENA
13 GND
GND
14
CLKIN Clock
15 CLKIN+
Clock +
16 GND
GND
17
Link3
See: *2) R0, R1, G0, G1, B0, B1
R6, R7, G6, G7, B6, B7
18 Link3+ See: *2) R0, R1, G0, G1, B0, B1 R6, R7, G6, G7, B6, B7
19 MODE Low=ISP 6 bit compatibility mode
High=ISP
8 bit compatibility mode
20 SC
Reverse scan control ( Low : Normal , High : Reverse )
*1) Metal frame is connected to signal GND.
*2) Recommended wiring of Pin 17,18 (6 bit input)
LOW data
LVDS
transmitter
6
8
0
Ω
6
2
0
Ω
V
CC
or
Pin 17
Pin 18
Pin 17
Pin 18