Mitsubishi MS-30SV Spécifications

Naviguer en ligne ou télécharger Spécifications pour Climatiseurs à système divisé Mitsubishi MS-30SV. Mitsubishi MS-30SV Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 179
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
CC-Link Compatible Product Catalog
CC-Link Compatible Product Catalog
Consumption tax is not included in the prices of
all products listed in this catalog. Please be
aware that consumption tax will be added to the
price at the time of purchase.
Precautions in Usage
This company shall not be liable for any
damage caused by reasons for which
this company is not responsible, loss of
opportunities on the part of the customer
due to the failure of our products, pas-
sive damage, damage caused by special
circumstances regardless of this compa-
ny's prior knowledge, secondary dam-
age, accident compensation, damage to
products other than ours, and guaran-
tees for other operations.
For Safe Usage
Please read the manual before using the products listed in this catalog to ensure that they are used correctly.
These products are created for general-purpose applications targeted for general industry, etc. They are neither de-
signed nor manufactured for use in devices or systems that operate under conditions that endanger human lives.
Please make inquiries to the sales window when considering applying these products for special purposes such
as devices and systems for atomic energy, electric power, aerospace, medical, or passenger-vehicle applica-
tions.
These products are manufactured in accordance with a strict system of quality control. Nonetheless, be sure to set
up systematic backup and fail safe functions if these products are used in equipment where a serious accident and
damage can be expected in the case of a product failure.
L
(
NA
)
08018E-B 0307
(
MEE
)
New publication, effective JUL. 2003
Specifications subject to change without notice.
Printed in Japan on recycled paper.
Open Field Network
CC-Link Compatible Product Catalog
Nagoya works, Mitsubishi Electric Corporation, has acquired certifi-
cation for systems of environmental management under ISO 14001,
and for quality management systems under ISO 9001.
Open Field Network
CC-Link Compatible Product Catalog
Country/Region Sales office Tel/Fax
U.S.A Mitsubishi Electric Automation Inc. Tel : +1-847-478-2100
500 Corporate Woods Parkway Vernon Hills, IL 60061 Fax : +1-847-478-2396
Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Tel : +55-11-283-2423
AV.Paulista 1471, Conj. 308, Sao Paulo City, Sao Paulo State, Brazil Fax : +55-11-288-3047
Germany Mitsubishi Electric Europe B.V. German Branch Tel : +49-2102-486-0
Gothaer Strasse 8 D-40880 Ratingen, GERMANY Fax : +49-2102-486-7170
U.K Mitsubishi Electric Europe B.V. UK Branch Tel : +44-1707-276100
Travellers Lane, Hatfield, Herts., AL10 8XB,UK Fax : +44-1707-278695
Italy Mitsubishi Electric Europe B.V. Italian Branch Tel : +39-039-6053344
Centro Dir. Colleoni, Pal. Perseo - Ingr.2 Fax : +39-039-6053312
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Spain Mitsubishi Electric Europe B.V. Spanish Branch Tel : +34-93-565-3131
Carretera de Rubi 76-80 Fax : +34-93-589-2948
08190 Sant Cugat del Valles, Barcelona, Spain
France Mitsubishi Electric Europe B.V. French Branch Tel : +33-1-5568-5568
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France Fax : +33-1-5568-5685
South Africa Circuit Breaker Industries LTD Tel : +27-11-928-2000
Tripswitch Drive, Elandsfontein Gauteng, South Africa Fax : +27-11-392-2354
Hong Kong Ryoden Automation Ltd. Tel : +852-2887-8870
10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Fax : +852-2887-7984
China Ryoden Automation Shanghai Ltd. Tel : +86-21-6475-3228
3F Block5 Building Automation Instrumentation Plaza 103 Fax : +86-21-6484-6996
Cao Bao Rd. Shanghai 200233 China
Taiwan Setsuyo Enterprise Co., Ltd. Tel : +886-2-2299-2499
6F., No.105 Wu-Kung 3rd.Rd, Wu-Ku Hsiang, Taipei Hsine, Taiwan Fax : +886-2-2299-2509
Korea HAN NEUNG TECHNO CO., LTD. Tel : +82-2-3660-9552
1F Dong Seo Game Channel Bldg., 660-11,Deungchon-dong Kangsec-ku, Fax : +82-2-3664-8372
Seoul, Korea
Singapore Mitsubishi Electric Asia Pte, Ltd. Tel : +65-6473-2308
307 Alexandra Road #05-01/02, Fax : +65-6476-7439
Mitsubishi Electric Bulding Singapore 159943
Thailand F. A. Tech Co.,Ltd. Tel : +66-2-682-6522
898/28,29,30 S.V.City Building, Office Tower 2, Floor Fax : +66-2-682-6020
17-18 Rama 3 Road, Bangkpongpang, Yannawa, Bangkok 10120
Indonesia P.T. Autoteknindo SUMBER MAKMUR Tel : +62-21-663-0833
Jl. Muara Karang Selatan Blok a Utara No.1 Kav. Fax : +62-21-663-0832
No.11 Kawasan Industri/Pergudangan Jakarta-Utara 14440
India Messung Systems Put,Ltd. Tel : +91-20-712-2807
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,PUNE-411026,India Fax : +91-20-712-0391
Australia Mitsubishi Electric Australia Pty. Ltd. Tel : +61-2-9684-7777
348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245
MITSUBISHI ELEC
T
R
IC CO
R
PO
R
A
T
ION
HEAD OFFICE: 1-8-12,OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN NAGOYA WORKS: 1-14,YADA-MINAMI 5,HIGASHI-KU,NAGOYA,JAPAN
Vue de la page 0
1 2 3 4 5 6 ... 178 179

Résumé du contenu

Page 1 - Open Field Network

CC-Link Compatible Product CatalogCC-Link Compatible Product CatalogConsumption tax is not included in the prices of all products listed in this catal

Page 2 - New Line up!

System the line-upCL1PAD1POWER+24V24GDBDA24GDBDA+24VLCNET/POWERLINKCL2Y8-TP1B2Y0Y1Y2Y3Y4Y5Y6Y740 20 108 4 2 1PWL RUNL ERR.STATION NO.0.5

Page 3 - (            )

98The GOT-A900/800 Series GOTs can be used in CC-Link.Communication Modules for HMI (GOT)Communication moduleCommunication moduleA8GT-J61BT13A8GT-J61B

Page 4 - Total Network Solution

99● OverviewCommunication Modules for HMI (GOT)● List of ModelsCC-Link connection module for GOT-A900/800 SeriesCC-Link connection module for GOT-A900

Page 5 - Plant Level

100A8GT-J61BT13Communication Modules for HMI (GOT)● Performance Specifications See page 154 for the general specifications.A8GT-J61BT13Intelligent de

Page 6 - ・CC-Link Family

● Name and Setting of Each Part101Communication Modules for HMI (GOT) A8GT-J61BT13● External Dimension DiagramTerminal blockLED displayNumber 

Page 7 - CC-Link Family

102A8GT-J61BT15Communication Modules for HMI (GOT)● Performance Specifications See page 154 for the general specifications.Model name Station type Nu

Page 8 - Features

● Name and Setting of Each Part103Communication Modules for HMI (GOT) A8GT-J61BT15● External Dimension DiagramDA DG NC NCDB SLD FG1 NC0594837261059483

Page 9 - Full RAS Functionality

104IBM PC/AT compatible PCs can be used as master/local stations of CC-Link.PC Interface BoardsPC equipped with PCI busLocal stationRemote I/O station

Page 10 - the line-up

105● OverviewPC Interface Boards● List of Models● Operating EnvironmentUser's ManualIB-0800175 (13JR28)User's Manual (SW3DNF-CC-link compati

Page 11 - System the line-up

106 PC Interface Boards● Performance Specifications See page 154 for the general specifications. A PC incorporating a PCI bus can be used as the maste

Page 12 - Application

● Name and Setting of Each Part107PC Interface Boards A80BDE-J61BT11 A80BDE-J61BT13● External Dimension Diagram● UtilityOperation LED displayTerminal

Page 13 - Automated warehouse

Communication Modulesfor HMI(GOT)P.98Optional PartsP.126SoftwareP.132Analog ModulesP.72OthersSpecial function moduleP.84P.88P.94P.1189System the line-

Page 14

108Various repeater modules expand the range of CC-Link adaptations and enhance the freedom of application.Repeater Modules● Overview Three types (fiv

Page 15 - Manufacturing

109Repeater Modules● List of ModelsIf the module is used in this way…?Select this!?!110112112110112114Selection conditionPage with detailed informatio

Page 16 - Products information

110 AJ65SBT-RPTRepeater Module● Performance Specifications See page 154 for the general specifications. A T-branch configuration can be included in th

Page 17 - Product Information

● Name and Setting of Each Part111Repeater Module AJ65SBT-RPT● External Dimension Diagram● System Configuration● Module ConnectionIN side terminal blo

Page 18 - Master/Local Modules

112 AJ65SBT-RPS AJ65SBT-RPGRepeater Module● Performance Specifications See page 154 for the general specifications. CC-Link system optical repeater mo

Page 19

● System Configuration113Repeater Module AJ65SBT-RPS AJ65SBT-RPG● External Dimension Diagram● Name and Setting of Each Part● Module ConnectionOptical

Page 20 - QJ61BT11N

114 Repeater Module Wireless transmission can be achieved by infrared light.。  By using AJ65BT-RPI-10A and AJ65BT-RPI-10B modules combined, it becomes

Page 21

● Name and Setting of Each Part115Repeater Module AJ65BT-RPI-10A AJ65BT-RPI-10B● Performance Specifications See page 154 for the general specificatio

Page 22 - AJ61QBT11

116● System Configuration*1 The repeater is a module used to connect each segment and extend the CC-Link system. AJ65BT-RPI-10A (module A) and A

Page 23

117● Module Connection● External Dimension DiagramTerminal resistorTerminal resistorTerminal resistorTerminal resistorMaster module Remote moduleLocal

Page 24 - A1SJ61QBT11

Application10・Application ExamplesBottle filling lineSystem example using CC-Link1The total extension distance of CC-Link is 1.2km (156kbps). However

Page 25

OverviewOverview118It is possible to perform data communication with external devices, such as bar-code readers and ID controllers that communicate vi

Page 26 - AJ61BT11

Overview119● OverviewRS-232 Interface Module● List of ModelAJ65BT-R2RS-232 interface moduleIntelligent device1 120Product name Model name DescriptionN

Page 27

120 AJ65BT-R2Product Description RS-232 Interface Module● Performance Specifications See page 154 for the general specifications. Interface specificat

Page 28 - A1SJ61BT11

● Name and Setting of Each Part● External Connection Diagram ● External Dimension Diagram121Product Description RS-232 Interface Module AJ65BT-R2● Ext

Page 29 - QJ61BT11

PWL RUNL ERR.0123456789ABCDEFCL2X16-D1M1VST.No.12345678LINK/PWINONCL1X2-D1D3SPWL RUN0STATION NO.4020108 4 2 1HLDCOMM.124GX0Y0+24VIN OUTCL1PAD1POWER+

Page 30 - FX2N-16CCL-M

123Q SeriesQnA SeriesA SeriesFX SeriesPCI BoardOthersModel of connectable master modulesQJ61BT11NAJ61QBT11, A1SJ61QBT11AJ61BT11, A1SJ61BT11FX2N-16CCL-

Page 31

● Performance Specifications See page 154 for the general specifications. Seamlessly connecting two networks The AJ65SBT-CLB is a bridge module that

Page 32 - Remote I/O Modules

125CC-Link-CC-Link/LT Bridge Module AJ65SBT-CLBA J65SBT− CLB (FG) ON 8 ERR. L ERR. RUN L L RUN ERR. PW L RATE RATE NC B NOS B STATION NO. TST 1 1 2

Page 33

OverviewOverview126Various optional parts are available for I/O modules.Optional PartsOne-touch connector plugOne-touch connector plug for communicati

Page 34

Overview127Optional PartsOnline connector for communicationOnline connector for power supplyApplicationAJ65VBTCU□-□type digital I/O moduleAJ65VBTCU-□t

Page 35

11Application ExamplesSystem example combining andImproved maintainabilityEase of connecting various sensorsCC-Link-CC-Link/LT bridge fo

Page 36

● List of Models● Wiring Method128 One-Touch Connector PlugOptional Parts for I/O ModulesA6CON-P214A6CON-P220A6CON-P514A6CON-P520The following are one

Page 37 - Can be designed arbitrarily

● List of Models129A6CON-L5PA6CON-PW5PA6CON-LJ5PA6CON-PWJ5PA6CON-TR11The following parts are provided for AJ65VBTCU□-□ type digital I/O modules and AJ

Page 38 - AJ65SBTB□-□ AJ65BTB□-□

● External Dimension Diagram● List of Models130 Protective coverOptional Parts for I/O Modules It is possible to prevent foreign substances from getti

Page 39

● List of Models● List of Models● List of Models131Protective Cap for Unused Connector AreasOptional Parts for I/O ModulesDust-proof cap (a pack conta

Page 40

● List of Models132 Configurator for CC-LinkSoftwarePrecautionFX PLCs cannot be used. The master station parameters for the Q and QnA Series PLC CPUs

Page 41

● List of Models133MELSEC Programming SoftwareSoftware● Operating EnvironmentOS CPU DisplayMemory hard disk space Disk driveCommunication interfaceOp

Page 42

134 ●Torque outputs as high as 150 percent is achieved at a low speed and 1 Hz.●FR-E540-□K uses the optional FR-A5NC inverter module, which means that

Page 43

135● Performance SpecificationsProductDescriptionAC Servo Amplifier / Interface moduleMR-J2S-□CP-S084/MR-J2S-T01ProductDescriptionProductDescription● 

Page 44

136 AC Servo Amplifier●This servo amplifier has a built-in positioning function, so a positioning controller is not required.●The best choice for high

Page 45

137● Performance SpecificationsProductDescriptionCNCMELDAS SeriesProductDescriptionProductDescriptionModel MELDAS C6516/801/65−−512/51240/60032000Step

Page 46

ApplicationCC-Link supports a number of different applications.● Main Requirements● Introducing CC-Link: Key Advantages● Main Requirements● Introducin

Page 47

138Industrial RobotRP, RV-A, RH-A, RV-T, RH/RC-G Series With its reinforced network functionality, this robot    controller can be used in various sy

Page 48

139ProductDescription<Robot>These robots are compatible with the controllers specified on the left side page. (Contact us for combination.) Smal

Page 49

140 ProductDescriptionDedicated CC-Link Communication LSIMFP1 MFP2 MFP2A MFP3● List of ModelsOrdering model nameMFP2MFP2AA6GA-CCMFP2N 60FFor remo

Page 50 - AJ65SBTC□-□ AJ65VBTCU□-□

141 This is an interface block used to connect Mitsubishi Mi-cro-PLCs of the FX0N, FX1N, FX2N, FX1NC and FX2NC Series to a CC-Link network as remote

Page 51

142 BreakerMDU Breaker● Performance Specifications Measured values Number of occupied stationsLoad current (current value, demand value, and maxi

Page 52

143ProductDescriptionPower Measurement ModuleModel name Phase/wire type Rated voltage Rated current Measured values Number of occupied statio

Page 53

144● Performance SpecificationsProductDescriptionMulti-Circuit Electric Power Measuring ModuleEMU-C7P4 - 6-A ProductDescriptionProductDescription Mul

Page 54

145Protective Relay Control power supply External dimensions/weight Number of occupied stationsC□□□-A□□D□ Common for 100 to 220 VDC and 100 to 2

Page 55 - Constant

146Technical informationFieldNetworkOpen

Page 56 - AJ65MBTL1N-□

Technical Information● Overview of CC-Link● General Specifications/Glossary147Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-

Page 57 - AJ65FBTA□-16□ AJ65SBTW4-16□

● Main Requirements ● Introducing CC-Link: Key Advantages● Main Requirements ● Introducing CC-Link: Key Advantages● Main Requirements● Introducing CC

Page 58

148Technical InformationOverview of CC-LinkCC-Link (Version1.10) SpecificationsMaximum number of link pointsNumber of link points per stationNumber of

Page 59

149Overview of CC-LinkT-Branch Communication Specification (When Repeater (T-Branch) Modules are not Used)Remote I/O / remote device stationRemote I/O

Page 60

150Cyclic transmissionTransient transmissionBit transmissionWord transmissionDedicated instructionIt is possible to communicate 32 input points and 32

Page 61 - 40 10 4 1 2208241

151MemoMaster/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link /

Page 62

152Differences Between Versions 1.10 and 1.00Specification List of CC-Link Version 1.00 (Differences from Version 1.10) The specifications of CC-Link

Page 63

153Overview of CC-Link With Ver. 2, the cyclic data size can be increased through extended cyclic setting.Differences Between Versions 2 and 1CC-Link

Page 64

General Specifications/GlossaryTechnical Information154*1:Interface boards for use in PCs depend on the PC used.*2:This indicates to which power-distr

Page 65

General Specifications/Glossary155● Glossary and Definition of AbbreviationsI/Omode……………………………Intelligent mode……………………Intelligent device station …………I

Page 66

156FieldNetworkOpenSupport

Page 67 - Module mounting screw

Support157● Overseas Support System ● CC-Link Partner Association (CLPA)From page 158From page 162Master/LocalRemote I/OAnalogHigh-SpeedCountersPosi

Page 68 - Remote I/O

14FieldOpenNetworkProducts information

Page 69 - AJ65BTC1-32D

Overseas Support SystemEssential S for Custom through a Truly Glob 158SupportNorth America FA CenterMitsubishi Electric Automation,Inc.500 Corporate

Page 70 - Unit: mm

upport ers al System159<PLCs, Inverters, Servos, HMIs> Overseas Support SystemBeijing FA CenterGangling Electronic Technology Development (Beiji

Page 71 - ● External Connection Diagram

Overseas Support System160Support● Service NetworkPlease consult the FA Center if you are not in Japan, just as you would consult a branch office in J

Page 72

161<Robots> Overseas Support System● Industrial Robots●Some products must be ordered from Japan. *Some services cannot be provided, depending on

Page 73

162Essential S for Custom through a Truly Glob North America FA Center North/South AmericaMitsubishi Electric Automation,Inc. Chicago [MEAU (IL)]500

Page 74 - Analog Modules

163 upport ers al System China/Hong KongRyoden Automation (Shanghai) Ltd.Beijing Office Beijin9/F,Office Tower 1,Henderson Center,18 Jianguomennei D

Page 75

CC-Link Partner Association (CLPA)SupportWhat is the CC-Link Partner Association?A conformance test is conducted for each model of all the CC-Link and

Page 76

165Global Support SystemThe CC-Link Partner Association has set up bases, not only in Japan but also in overseas locations in order to pursue expansio

Page 77

166IndexFieldNetworkOpen

Page 78 - AJ65SBT-64AD AJ65BT-64AD

List of Models/Index167● List of Models● Index of ModelsFrom page 168From page 172

Page 79 - AJ65BT 64RD

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 80 - AJ65VBTCU-68DAVN

168AJ61BT11A1SJ61BT11AJ61QBT11A1SJ61QBT11QJ61BT11NFX2N-16CCL-MAJ65FBTA4-16DAJ65FBTA4-16DEAJ65SBTB1-8DAJ65SBTB1-16DAJ65SBTB1-16D1AJ65SBTB1-32DAJ65SBTC4

Page 81

169IP2X IP2X IP2X IP2X IP2X IP2X IP1XAJ65BTB1-16TAJ65BTB2-16TAJ65BTC1-32TAJ65BTB2-16RAJ65BTB1-16DTAJ65BTB2-16DTAJ65BTB2-16DR16-point 12/24VDC (0.5 A),

Page 82 - Internal current

List of CC-Link Related Product Models170AJ65BT-R2AJ65BT-G4-S3A8GT-J61BT13A8GT-J61BT15A80BD-J61BT11A80BD-J61BT13AJ65SBT-RPTAJ65SBT-RPSAJ65SBT-RPGAJ65B

Page 83 - 4.5mm mounting holes

171Product name Model nameProduct name Model nameProduct name Model nameProduct name Model nameSpecificationSpecificationSpecification One-Touch Conne

Page 84 - Analog Module

Index of CC-Link Related Product Models172Index of CC-Link Related Product Models Index of Models (in alphabetic order)List of Models/IndexACEFMQRSAJ6

Page 85

173Memo

Page 87

175Memo

Page 89 - J65BT-D62

CC-Link Compatible Product CatalogCC-Link Compatible Product CatalogConsumption tax is not included in the prices of all products listed in this catal

Page 90 - Positioning Module

16QJ61BT11N AJ61QBT11FX2N-16CCL-MA1SJ61QBT11AJ61BT11A1SJ61BT11Master/local modules control the CC-Link system with total freedom.Master/Local ModulesO

Page 91

Model nameQJ61BT11NAJ61QBT11A1SJ61QBT11AJ61BT11A1SJ61BT11FX2N-16CCL-M1 The number of occupied stations at a local station is set by a parameter in GX

Page 92 - AJ65BT-D75P2-S3

New Line up!The " " logo is printed on the products compatible with CC-Link Ver. 2. Master Module for Q Series QJ6

Page 93 - 

● Features18For Q CPUQJ61BT11NMaster/Local ModuleIt is possible to set the CC-Link parameters from the parameter setting sc

Page 94

● External Dimension Diagram19Functions for CC-Link: Cyclic transmission, expanded cyclic transmission, transient transmission, station-to-station

Page 95

● Features● Specification See page 154 for the general specifications. Internal current consumption 0.45 AWeight 0.4 kg  See page 148 for the CC-L

Page 96 - AJ65BT-G4-S3

● External Dimension Diagram21LED displayRUNERR.MSTS MSTLOCALCPU R/WERRORL RUNL ERR.B RATESDRDOn: The module is normal.On: Communication error for all

Page 97

● Features● Specification See page 154 for the general specifications. Internal current consumption 0.4 AWeight 0.25 kg  See page 148 for the CC-L

Page 98

● External Dimension Diagram23LED display Mode setting switchThis is used for setting the module's operation mode.Station number setting switches

Page 99 - AJ65BT-G4-G3

 Internal current consumption 0.45 AWeight 0.4 kg  See page 148 for the CC-Link common specifications.24A0J2(H)CPUAnSCPUA1SCPUC24-R2AnSHCPUAnUSCPU

Page 100 - Communication module

25LED displayIt is possible to check the data link condition by the on/off status of the LED display.AJ61BT11STATION NO. X10 X1 MODE0:ONLINE(A.R.) 1:O

Page 101 - Overview

 Internal current consumption 0.4 AWeight 0.25 kg  See page 148 for the CC-Link common specifications.26F

Page 102 - A8GT-J61BT13

2710864297531NCDANC(FG)SLDNCNCNCDBDGA1SJ61BT11A1SJ61BT1112345678O N K S D 0 8STATION NO. MODEX10X1B RATE0 156K1 625K2 2. 5M35M4 10M12345678M / LCLR1

Page 103 - BD999C127H01

Contents Total Network Solution CC-Link Family Features of CC-Link System Configuration Examples Application Examples Application Examples

Page 104 - A8GT-J61BT15

(Remote I/O station)(Remote I/O station)(Remote device station)(Remote device station)(Master station) Internal current consumption (5 VDC): 5 VDC su

Page 105

29Master Block FX2N-16CCL-M● Name and Setting of Each PartNumberSW 1 to 3SW4SW 5 to 8Setting

Page 106 - PC Interface Boards

Product description Page 36 Product description Page 48OverviewOverviewProduct description Page 58 Product description Page 66NewProduct description P

Page 107 - (           )

Overview31Remote I/O Modules● Overview A remote I/O module occupies one remote I/O station. Installation on the control board can be done either wit

Page 108

32Remote I/O Modules● List of ModelsInput moduleI/O moduleOutput moduleCompact type remote I/O moduleCompact type remote I/O moduleCompact type remot

Page 109 - BD808C083G51

33Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBri

Page 110 - Repeater Modules

GuideMaster/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LT

Page 111 - Selection of Repeater Modules

AJ65SBTB□-□AJ65VBTCU□-□AJ65MBTL1N-□AJ65SBTB3-□AJ65SBTC4-□AJ65VBTCU□-□AJ65FBTA□-□AJ65SBTW4-□AJ65SBTC□-□AJ65VBTCU□-□AJ65SBTB1-□D1AJ65SBTB1-□DT1AJ65SBTB1

Page 112 - AJ65SBT-RPT

3612/24 VDC12/24 VDC12/24 VDC12/24 VDC12/24 VDC12/24 VDC12/24 VDC12/24 VDC12/24 VDC12/24 VDC12/24 VDC12/24 VDC24 VDC/240 VAC24

Page 113

AJ65SBTB1-8DX01234567X0 X2 X4 X6X1 X3 X5 X7DA DG +24V 24GDB SLD(FG)COMCOM124124102040 8ONSTATION NO. B RATE40 20 10 8 4 2 1 4 2 1B RATESTATION NO.ONAJ

Page 114 - AJ65SBT-RPS AJ65SBT-RPG

Total Network Solution2・Total Network SolutionQ12HCPUUSBPULLRS-232QX42-S1QY42PPULLPOWERQ25HCPUUSBQX42-S1QY42PPULLMODERUNERRUSERBATBOOTMODERUNERRUSERBA

Page 115

38AJ65SBTB1-8AJ65BTB1-16AJ65BTB2-16AJ65SBTB1-16AJ65SBTB2-8AJ65SBTB3-8AJ65SBTB2N-8AJ65SBTB32-8AJ65SBTB1-32AJ65SBTB2-16AJ65SBTB3-1

Page 116 - Repeater Module

39Input Module● External Connection DiagramRemote I/O AJ65SBTB□-□ AJ65BTB□-□ AJ65SBTB1-8D type AJ65SBTB1-16D type, AJ65SBTB1-16D1 type

Page 117 - Description

AJ65BTB1-16D typeAJ65SBTB3-16D typeAJ65SBTB3-8D typeAJ65SBTB2N-16A typeInput ModuleAJ65BTB2-16D type40● External Connection DiagramRemote I/O A

Page 118 - ● System Configuration

41● External Connection DiagramRemote I/O AJ65SBTB□-□ AJ65BTB□-□ AJ65SBTB1-8T typeAJ65SBTB1-32T type AJ65SBTB1-32T1 typeModule power

Page 119 - ● External Dimension Diagram

Output ModuleAJ65SBTB1-16TE typeAJ65SBTB2-16T type 

Page 120 - RS-232 Interface Module

Output ModuleAJ65SBTB2N-8R typeAJ65SBTB2N-8S typeAJ65SBTB2N-16R typeAJ65SBTB2N-16S type43● External Connection DiagramRemote I/O AJ65SBTB□-□ AJ6

Page 121

44● External Connection DiagramRemote I/O AJ65SBTB□-□ AJ65BTB□-□ Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232Interfac

Page 122 - AJ65BT-R2

I/O ModuleAJ65SBTB1-16DT,AJ65SBTB1-16DT1 typeAJ65SBTB1-32DT,AJ65SBTB1-32DT1 type AJ65SBTB1-32DT2, AJ65SBTB1-32DT3 typeAJ65SBTB1-16DT2, AJ65SBTB1-1

Page 123

AJ65SBTB32-8DT typeAJ65SBTB32-16DT typeI/O Module typeModule power supplyIsolation

Page 124 - AJ65SBT-CLB

I/O ModuleAJ65BTB1-16DT typeAJ65BTB2-16DR typeDADBDGSLD+24VFG24GX0X1X2X3X4X5X6X7COM1+NCY8Y9YAYBYCYDYEYFCOM2-CTL2+DC/DCRR1234567891011121314151617181

Page 125

Total Network Solution3MELSECNET/HEthernetCC-LinkCC-Link /LTQ12HCPUUSBPULLRS-232QX42-S1QY42PPULLPOWERQ25HCPUUSBQX42-S1QY42PPULLMODERUNERRUSERBATBOOTMO

Page 126

48AJ65SBTC1-32DAJ65SBTC1-32D1AJ65SBTC4-16DAJ65VBTCU3-8D1AJ65VBTCU3-16D1DC inputDC inputDC inputDC inputDC inputPhotocouplerPhotocouplerPhotocouplerPho

Page 127

49● Name and Setting of Each PartRemote I/O AJ65SBTC□-□ AJ65VBTCU□-□ 4020108421421STATION NOB RATEAX0X1X2X3X4X5X6X7PWL RUNL ERR01234567J65VBTCU3-8D1

Page 128 - Optional Parts

50AJ65SBTC1-32AJ65SBTC4-16AJ65VBTCU-8AJ65VBTCU-1640DBDASLDDG +24V 24G(FG)COMCOMPW L RUN L ERR X0 1 2 3 4 5 6 7 X8 9 A B C D E F40 20 10 8 4

Page 129

51Input Module● External Connection DiagramRemote I/O AJ65SBTC□-□ AJ65VBTCU□-□ AJ65VBTCU3-16D1 typeSource input

Page 130 - A6CON-P520

52Output Module● External Connection DiagramRemote I/O AJ65SBTC□-□ AJ65VBTCU□-□ Module

Page 131 - A6CON-TR11

53● External Connection DiagramRemote I/O AJ65SBTC□-□ AJ65VBTCU□-□ I/O power supply(external power supply) 

Page 132 - A6CVR-8 A6CVR-16 A6CVR-32

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 133 - A6PLT1V A6PLT2V

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 134 - GX Configurator-CC

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 135 - GX Developer

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 136 - FREQROL-□500

Family4・CC-Link FamilyTo expand open network possibilities to every corner of a field.The CC-Link family realizes flexible system configuration.For ma

Page 137 - MR-J2S-□CP-S084/MR-J2S-T01

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 138 - AC Servo Amplifier

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 139 - MELDAS Series

60Terminal resistor setting switchTerminal resistor setting switch● External Dimension DiagramRemote I/O AJ65FBTA□-16□ AJ65SBTW4-16□ AJ65FBTA4-16D,

Page 140 - Industrial Robot

61AJ65FBTA4-16D AJ65FBTA4-16DE 

Page 141

62Terminal resistor setting switchTerminal resistor setting switchAJ65FBTA2-16T 

Page 142 - MFP1 MFP2 MFP2A MFP3

63  

Page 143 - FX2N-32CCL

64● External Connection DiagramRemote I/O AJ65FBTA□-16□ AJ65SBTW4-16□ AJ65SBTW4-16DSink inputSource input 

Page 144 - MDU Breaker

65MemoModule mounting screwModule mounting screwModule mounting screwMaster/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232Interf

Page 145 - EMU-C3P5 EMU-C3P5-5A

  X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NCX0 X1 X2 X3 X4 X5 X6 X7 X8 X9

Page 146 - EMU-C7P4 - 6-A

67Remote I/O AJ65SBTCF□-□ AJ65VBTCF□-□ AJ65BTC□-□ ● Name and Setting of Each PartCON.A CON.BPWLINKX0 XFCON.C CON.DPW/AUX.L RUNL ERR0 1 2 3 4 5 6 7

Page 147 - MELPRO-D Series

5CC-Link FamilyRemote I/O stationsFast response Ease of working by connection of connectorsEase of extension and addition Communication and powe

Page 148 - Technical information

68AJ65SBTCF1-32AJ65BTC1-32STATION NO.X10 X1MITSUBISHI5014623501469237801423AJ65BTC1-32D0PW123456789ABCDEFL RUN SD RD L ERR.0123456789ABCDEFABDA D

Page 149 - Technical Information

69I/O ModuleAJ65SBTCF1-32DT11234512345DADBDGNCSLDLINK CABLE(IN)One-touch connector for communicationCON.A1234512345DADBDGNCSLDLINK CABLE(OUT)UNIT POW

Page 150 - Overview of CC-Link

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 151

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 152

NewNewMaster/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / L

Page 153

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 154

74Model name AJ65VBTCU-68ADVN AJ65VBTCU-68ADINAnalog inputDigital valueInput/output characteristicsInput range switchingOffset/gain settingMaximum con

Page 155

● External Connection Diagram ● External Dimension Diagram75Operating condition LED display Connector for communicationConnector for analog I/OConnect

Page 156

Master/LocalRemote I/OAnalogHigh-SpeedCountersPositioningHMIRepeatersRS-232InterfacesOptionSoftwareOthersTechnicalInformationCC-Link-CC-Link / LTBridg

Page 157

● 各部の名称と設定 AJ65BT-64AD

Page 158

Features6・Features of CC-LinkCC-Link is a high-performance network that utilizes high speed communications (10 Mbps industry fastest), in order to all

Page 159 - From page 162

78Model nameAJ65VBTCU-68DAVNDigital valueAnalog outputInput/output characteristicsAccuracy(Accuracy relative to the maximum analog output value)Outp

Page 160 - Truly Glob

79For wire, use two-core shielded twisted-pair cable.Connect a capacitor of around 0.1 to 0.47 µF (it must be a product that can withstand voltages of

Page 161 - ●  List of Service Models

80Analog OutputTwo channelsDigital values from 4000 to 4000 or from 0 to 4000 can be converted to analog val-ues of 10 V to 10 V or 0 mA to 2

Page 162

81Analog Modules AJ65SBT-62DA AJ65BT-64DAV AJ65BT-64DAIAJ65SBT-62DA ● Name and Setting of Each PartAJ65BT-64DAV / 64DAI● Name and Setting of Each P

Page 163 - ● Industrial Robots

82● AJ65BT-68TD● AJ65BT-64RD3 / 64RD4Model nameMeasurement methodConnectable platinum resistance temperature sensorsConnectable thermocouplesTemperat

Page 164

● Name and Setting of Each PartAJ65BT-64RD3/64RD483Analog Modules AJ65BT-68TD AJ65BT-64RD3 AJ65BT-64RD4AJ65BT-68TD ● Name and Setting of Each Part1

Page 165 - al System

84AJ65BT-D62AJ65BT-D62DAJ65BT-D62D-S1Pulses from pulse generators and similar equipment can be acquired and counted. High-Speed Counter ModulesOvervie

Page 166 - Europe (UK)

● List of Models85 All the high-speed counter modules are remote-device stations. It is possible to select from three types of counter modules, depe

Page 167 - Global Support System

86 Large counting range, from 0 to 16777215 (24-bit binary). External input: 5/12/24 VDC (2 to 5 mA) It is possible to multiply the count value. I

Page 168

87● Name and Setting of Each PartHigh-Speed Counter Module AJ65BT-D62 AJ65BT-D62D AJ65BT-D62D-S1RESETB RATE STATION NO.X10 X15069278134506213402134R

Page 169 - List of Models/Index

7Features of CC-LinkCC-Link can transmit bit data and word data at high speed with cyclic transmission, and the transmission time is stable as well (g

Page 170

88AJ65BT-D75P2-S3Complicated positioning control tasks can be handled by reading various signals, parameters and data, and by implementing the control

Page 171 - Page describing

89 It is possible to use the positioning function equivalent to positioning modules AD75P2-S3 and A1SD75P2-S3 of the MELSEC-A Series in a CC-Link sla

Page 172

90 Number of control axesInterpolation functionControl methodControl unitPositioning dataPeripheral device/software packageTeaching m

Page 173

Rated plateTwo 4.5mm mounting holes91● Name and Setting of Each PartPositioning Module AJ65BT-D75P2-S3These LEDs indicate

Page 174

92Example of Connection between D75P2 and MR-J2/J2S-A (Differential Driver (Open Collector), Negative Logic 5)"AD75C20SNJ2 type cable (for

Page 175

93 Example of Connection for Performing Absolute Position RecoveryThe servo on signal is switched off in case of an alarm signal, shutting down the m

Page 176

OverviewOverview94Module for operating PLC CPU remotely via CC-LinkPeripheral Device Connection ModuleAJ65BT-G4-S3Product description Page 96Master/Lo

Page 177

Overview95● OverviewPeripheral Device Connection Module● List of ModelsPeripheral device connection modulefor the GPP functionIntelligent

Page 178

96AJ65BT-G4-S3Peripheral Device Connection Module● Performance SpecificationsModel name Peripheral device connector Station type Number of occupied s

Page 179

● Name and Setting of Each Part97Peripheral Device Connection Module AJ65BT-G4-G3● External Dimension DiagramRated plateTwo 4

Commentaires sur ces manuels

Pas de commentaire