SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
ADVANCE AND EVER ADVANCING
TECHNICAL & SERVICE MANUAL
<indoor unit> Service ref.
Models
PEHD-1.6EKA2.UK
PEHD-1.6EKHA
2.UK
PEHD-2EKA
2.UK
PEHD-2EKHA
2.UK
PEHD-2.5EKA
2.UK
PEHD-2.5EKHA
2.UK
The Slim Line.
From Mitsubishi Electric
TM
1. FEATURES ················································ 1
2. PART NAMES AND FUNCTIONS ············· 2
3. SPECIFICATIONS······································ 5
4. DATA··························································· 8
5. REFRIGERANT SYSTEM DIAGRAM ·······13
6. OUTLINES AND DIMENSIONS ················14
7. WIRING DIAGRAM ··································· 15
8. DISASSEMBLY INSTRUCTIONS ············ 16
9. PARTS LIST·············································· 19
10
. OPTIONAL PARTS··································· 23
CONTENTS
INDOOR UNIT
REMOTE CONTROLLER
This manual does not cover the
following outdoor units. When
servicing them, please refer to
the service manual No.OC150A
and this manual as a set.
PUH-1.6VKA
3.UK
PUH-2VKA
2.UK
PUH-2.5VKA
2.UK
2000
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - REMOTE CONTROLLER

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERSADVANCE AND EVER ADVANCINGTECHNICAL & SERVICE MANUAL<indoor unit> Service ref.ModelsPEHD-1.6EKA2.UKPEH

Page 2

4DATA8Service Ref.Indoorintake airWB˚C20 25 30 35 40 45CA P.C. CA P.C. CA P.C. CA P.C. CA P.C. CA P.C.1. PERFORMANCE DATA1) COOLING CAPACITYNote C A:

Page 3 - FEATURES

92. PERFORMANCE CURVEPEHD-1.6EK(H)A2.UKPEHD-2EK(H)A2.UKPEHD-2.5EK(H)A2.UKCooling1.41.210.80.61.41.210.80.6 0.41.41.210.80.61.41.210.80.6 0.4222018

Page 4 - PART NAMES AND FUNCTIONS

Fan Performance <30Pa>External static pressure (Pa)(1Pa 0.1mmAg)Air Flow (CMM)86101214166810121416204060801000.80.91.01.1Corrected Air FlowC

Page 5 - ● Operation buttons

11PEHD-2.5EK(H)A2.UKFan Performance <30Pa>External static pressure (Pa)(1Pa 0.1mmAg)Air Flow (CMM)8 101214161820222412 14 16 18 20 22 24 262

Page 6 - ● Display

12ModelsIndoorOutdoorModeCapacity(W)Total input(kW)Input(kW)Current(A)Starting current(A)Input(kW)Current(A)Starting current(A)IndoorOutdoorIndoor ···

Page 7 - SPECIFICATION

Indoor unitIndoor heat exchangerStrainerRestrictorvalveThermistorTH2Distributorwith strainerCapillarytubePEHD-1.6(OD3.2xID1.6xL630)PEHD-2(OD3.2xID

Page 8

1010301525617640A81 C B 81292276181AE 13131632828545 802772130 640 30243510179109103.53.525628840176Set10-ø3 (1.6, 2HP)12-ø3 (2.5HP)10-ø3 (1.6, 2HP)12

Page 9

7WIRING DIAGRAM156554631221343 1256789091043 1287564312431243 124321213214321321##******·····Only models PEHD-1.6,2,2.5EK(H)A#····Option partsSYMBOLTB

Page 10 - 1. PERFORMANCE DATA

8DISASSEMBLY INSTRUCTIONS16Figure1.Disconnect the fan motor connecter(and the booster heater connector)Drain pancatches (Hidden)Dr

Page 11

Screw holesBooster heater17Figure3.Booster heaterFan baseSirocco fanSirocco fanHousing assemblyHousing assemblyPiecePieceLegBushBushMotor22.

Page 13 - PEHD-2.5EK(H)A2.UK

18Pump coverassemblyDrain socketDrain pan coverDrain pumpassemblyDrain hoseRubber plugDrain pan123. Removing the drain water lift-up pump1. Remove the

Page 14 - 4. ELECTRICAL DATA

9PARTS LIST19PEHD-1.6EKA2.UK, PEHD-1.6EKHA2.UKPEHD-2EKA2.UK, PEHD-2EKHA2.UKPEHD-2.5EKA2.UK, PEHD-2.5EKHA2.UKEXTERNAL PARTS10, 111.28, 93, 45, 6, 7No.1

Page 15 - REFRIGERANT SYSTEM DIAGRAM

20PEHD-1.6EKA2.UK, PEHD-1.6EKHA2.UKPEHD-2EKA2.UK, PEHD-2EKHA2.UKPEHD-2.5EKA2.UK, PEHD-2.5EKHA2.UKBLOWER PARTS5, 67, 811449, 10, 11127, 85, 62, 313, 14

Page 16 - OUTLINES & DIMENSIONS

21PEHD-1.6EKA2.UK, PEHD-1.6EKHA2.UKPEHD-2EKA2.UK, PEHD-2EKHA2.UKPEHD-2.5EKA2.UK, PEHD-2.5EKHA2.UKCONTROL BOX PARTS67410582193No.12345678910Part No. Pa

Page 17 - WIRING DIAGRAM

22PEHD-1.6EKA2.UK, PEHD-1.6EKHA2.UKPEHD-2EKA2.UK, PEHD-2EKHA2.UKPEHD-2.5EKA2.UK, PEHD-2.5EKHA2.UKELECTRICAL PARTSNo.12Part No. Part Name Drawing No.KA

Page 18 - Fan base

23PEHD-1.6EKA2.UK, PEHD-1.6EKHA2.UKPEHD-2EKA2.UK, PEHD-2EKHA2.UKPEHD-2.5EKA2.UK, PEHD-2.5EKHA2.UKDRAIN WATER LIFT-UP PUMP PARTS (OPTIONAL PARTS)341.25

Page 19 - . Removing the booster heater

2410OPTIONAL PARTS1. REFRIGERANT PIPES28˚C26˚C8:00Normaioperation8:00Normaioperation23:00Setbackoperation2. TIMER2-1 Program timer specifications2-2

Page 20

252-3 HOW to connect program timer(1) Install the program timer next to the remote controller the same way as the remote controller is installed.(2)

Page 21 - PARTS LIST

261171171211311356.523.5 118"ENGAGED" indicatorWhen this indicator is lit, transmisson is in progress and all swiches are inoperative.

Page 22 - BLOWER PARTS

275-3 Connection method(1) Connection in the power supply cord.1. Connect the power supply cord to the power supply terminal-block and fix in-place wi

Page 23 - CONTROL BOX PARTS

11. NEXT GENERATION AIR-CONDITIONING VENTILATION INTERLOCKING SYSTEM "Mr.SLIM" +"LOSSNAY"Proper ventilation is important to impro

Page 24 - ELECTRICAL PARTS

28Fig. 1TERMINAL-BLOCKFORTRANSMISSIONDip switchSW 1Transmission cordTRANSFORMERFuse(5A)TERMINAL-BLOCKFOR POWERSUPPLYPOWER SUPPLY CORDTerminal block fo

Page 25

29(3)Connections from adapter6-3 Dimensions (Unit:mm)Fig. 3To program timer orcentralized remotecontrol

Page 26 - OPTIONAL PARTS

HEAD OFFICE MITSUBISHI DENKI BLDG. MARUNOUCHI TOKYO100 TELEX J24532 CABLE MELCO TOKYOMEE00K027Issued in Nov. 2000Printed in JapanNew publication, effe

Page 27 - 3. TIMER ADAPTER

26. ADVANCED MICROPROCESSOR(1) Easy to use microprocessor1) Ultra-thin remote controllerThe streamlined, square controller is designed to blend well w

Page 28 - 5-2 Functions

3This switches between continu-ous operation and the timer operation.Press this button to switch the cool, electronic dry (dehumidify) automatic and

Page 29 - OF POWER SUPPLY

4This indicates when the unitis controlled by optinal fea-tures such as central control type remote controller.The current time, start time and stop t

Page 30 - 6-2 Connection method

3SPECIFICATION5ItemFunctionCapacityTotal inputINDOOR UNITModel namePower supplyStarting currentRunning currentInputExternal finishHeat exchangerFan(dr

Page 31 - 7. OPTIONAL REMOTE CONTROLLER

6ItemFunctionCapacityTotal inputINDOOR UNITModel namePower supplyStarting currentRunning currentInputExternal finishHeat exchangerFan(drive) x No.Fan

Page 32 - Printed in Japan

7ItemFunctionCapacityTotal inputINDOOR UNITModel namePower supplyStarting currentRunning currentInputExternal finishHeat exchangerFan(drive) x No.Fan