Mitsubishi PAC-YG60MCA Spécifications

Naviguer en ligne ou télécharger Spécifications pour Climatiseurs à système divisé Mitsubishi PAC-YG60MCA. Mitsubishi PAC-YG60MCA Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
CITY MULTI
MEE11K010
New publication effective Oct. 2011
Specifications subject to change without notice
CM11AS-
MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS Series
The Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series
9000 of the International Standard Organization (ISO) based on a review of Quality management for
the production of refrigeration and air conditioning equipment.
ISO Authorization System
The ISO 9000 series is a plant authorization system relating to quality management as stipulated by
the ISO. ISO 9001 certifies quality management based on the "design, development, production,
installation and auxiliary services" for products built at an authorized plant.
FM33568 / ISO 9001;2008
The Air Conditioning & Refrigeration Systems Works acquired environmental management system
standard ISO 14001 certification.
The ISO 14000 series is a set of standards applying to environmental protection set by the
International Standard Organization (ISO).
Registered on March 10, 1998.
Eco Changes is the Mitsubishi Electric Group’s environmental statement,
and expresses the Group’s stance on environmental management.
Through a wide range of businesses, we are helping contribute to the
realization of a sustainable society.
Warning
Do not use refrigerant other than the type indicated in the manuals provided with the unit and on the nameplate.
- Doing so may cause the unit or pipes to burst, or result in explosion or fire during use, during repair, or at the time of disposal of the
unit.
- It may also be in violation of applicable laws.
- MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong
type of refrigerant.
http://Global.MitsubishiElectric.com
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - CITY MULTI

CITY MULTIMEE11K010New publication effective Oct. 2011Specifications subject to change without noticeCM11AS-MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AI

Page 2 - Our Latest Technologies

PAC-YT51CRBSimple remote controller PAC-YT51CRB (MA)Wired ME remote controller PAR-F27MEA• This remote control requires non-polar wiring to only one i

Page 3 - yet simple technology

Page 19Remote ControllerPage 20Remote ControllerSystem structureTouch controller AT-50AWith our new Advanced Touch Controller AT-50A, easy and simple

Page 4 - Unbeatable Efficiency

ON/OFF remote controller PAC-YT40ANRACentralizedRemote ControllerFUNCTIONUNITSON/OFFERROR INDICATIONVENTILATION OPERATION(INDEPENDENT)VENTILATION OPER

Page 5 - Total Energy Conservation

System structureSystem structureCentralized controller AG-150AWith a new colored touch panel, and continuation of all the G-50A functions,

Page 6 - For the Environment

Annual / Weekly Schedule Enables Weekly and Annual scheduling with a registering license • ON/OFF, operation mode, temperature setting, prohibit

Page 7

Dimension: 200(W) x 120(H) x 45(D) mm : 7-7/8(W) x 4-3/4(H) x 1-13/16(D) in.No more PLCs are needed!Our new DIDO controller makes it p

Page 8 - A ir-Conditioning

LMAPLMAPM-NETLMAP 02LMAPCITY MULTILMAPExample of System ConfigurationSystem design made simple through integration ofvarious devices into a total cont

Page 9

I ndoor unitCeiling cassette type 4-way airflow Ceiling cassette type 2-way airflow Ceiling cassette type 1-way airflow Ceiling concealed typeFresh Ai

Page 10 - Functions

PLFY-P VBM-EPLFY-P VCM-EINDOOR UNITCeiling cassette type4-way airflow The new 4-way cassette VBM offers 72 different airflow patterns, making it ideal

Page 11 - Touch Controller

INDOOR UNITCeiling cassette type2-way airflow PLFY-P VLMD-EFresh air can be taken in to the main unit directly (optional accessories needed.)The drain

Page 12 - Remote Controller

V RF systemVRF stands for Variable Refrigerant Flow. A VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requi

Page 13

mm (in.)198(7-13/16)PMFY-VBM230(9-11/16)max.402(15-7/8)max.600 (23-5/8)Compact and lightweight body perfect for limited ceiling space applications.Uni

Page 14

INDOOR UNITCeiling concealed typePEFY-P VMR-E-L/RIt is possible to operate / stop by taking a key card in and out. Quiet indoor environment can be

Page 15

The ultra thin unit of 200mm offers increased flexibility, and is particularly suitable for places where low noise operation is desired from a slim li

Page 16 - LONWORKS

PEFY-P VMA(L)-EINDOOR UNITCeiling Concealed TypeWith precise control of indoor temperature while operating with optimum energy usage, it offers a high

Page 18 - PLFY-P VBM-E

Capacity P503427P633832P713932P804135P1004234P1254234P1404234Sound pressureLeveldB(A)Sound pressure level table (Standard static pressure 220V)HighLow

Page 19 - PLFY-P VLMD-E

Fresh Air can be taken in with temperature control. Ideal for Offices, Stores and Restaurants.The Fresh Air intake indoor unitcan be installed in any

Page 20 - 1-way airflow

Designed for ultra-quiet operation and easy maintenance, provides exceptionally comfortable air-conditioning.PCFY-P VKM-EINDOOR UNITCeiling suspended

Page 21 - PEFY-P VMR-E-L/R

P20P15Capacity P25 P32 P40 P50VBM*VHMVKMP63 P100Capacity rangePKFY-P VBM-EPKFY-P VHM-EPKFY-P VKM-EINDOOR UNITWall mounted typeElegant Design and Compa

Page 22 - PEFY-P VMS1(L)-E

PFFY-P VKM-EINDOOR UNITFloor standing exposedFor living rooms, bed rooms, or offices where a sophisticated design is required. The latest Mitsubishi i

Page 23 - Ceiling Concealed Type

Designed and manufactured to the highest standards, the CITY MULTI range offers one of the most reliable air conditioning systems available. Simple to

Page 24 - *Metal Blower

Compact unit for easy air conditioning in perimeter zones.PFFY-P VLEM-EINDOOR UNITFloor standing exposedIts basic design is suitable for various locat

Page 25 - Ceiling concealed

Easily installable floor-standing concealed unit for perimeter zonePFFY-P VLRM-EPFFY-P VLRMM-EINDOOR UNITFloor mounted concealed typeThe unit is desig

Page 26 - PEFY-P VMH-E-F

The secret to the unmatched comfort provided by Lossnay core is the cross-flow, plate-fin structure off the heat-exchange unit. A diaphragm made of a

Page 27 - Ceiling suspended type

ADVANTAGESClean air supply, dirty air exhaust by Two air paths (OA SA and RA EA)Energy recovery by LOSSNAY CoreFree cooling by bypass dampe

Page 28 - Wall mounted type

In addition to the automatic damper open/close function, open/close control via external devices is now possible, delivering a “By-pass” ventilation s

Page 29 - Floor standing exposed

Ventilation modeFan speedCurrent (A) Power consumption (W) Air volumeModelExternal static pressure Temperature exchange efficiency (%)Enthalpy exchang

Page 30 - PFFY-P VLEM-E

ControlThe New Remote Controller PZ-60DR-E enable simple control settingCentralized Controller SystemLOSSNAY independentInterlocked with Air condition

Page 31 - Floor mounted concealed type

The OA Processing Unit is equipped with a new permeable film humidifier developed and patented by Mitsubishi Electric. Steam transmission efficiency h

Page 32 - 16°C (60.8°F)

The two-pipe zoned system designed for Heat Pump OperationThe CITY MULTI S series (for small applications) and Y series (for large applications) make

Page 33 - Energy Saving by timer

Y seriesThe anti-corrosion Blue Fin treatment of the heat exchanger is especially effective in urban environments where the traffic pollutions can dam

Page 34 - Model line up

The unique Heat Interchange Circuit (HIC) enhances efficiency by providing additional sub-cooling and allows the expansion device to effectively contr

Page 35 - LGH-15~100RX5-E

Heat Pump Series - High COPY Series - High COP (8HP-12HP)PUHY-EP YJM-A(-BS)Page87Wide selection of outdoor units* The PUHY-EP-YSJM-A(1) series require

Page 36 - VL-100U-E

PUMY-P YHMB(-BS)OUTDOOR UNITS SeriesSpecificationsPower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal)Temp. range of

Page 37 - RDH3 SERIES

PUHY-P YHA(-BS)OUTDOOR UNITY SeriesSpecificationsPower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal)Temp. range of h

Page 38 - O utdoor unit

PUHY-P YSHA(-BS)OUTDOOR UNITY SeriesSpecificationsSet namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal)Temp. r

Page 39 - Y series

PUHY-P YSHA (-BS)OUTDOOR UNITY SeriesSpecificationsSet namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capaci

Page 40 - Heat Pump Series

PUHY-P YSHA(-BS)OUTDOOR UNITY SeriesSpecificationsSet namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal )Temp.

Page 41 - Specifications

PUHY-EP YJM-A(-BS)OUTDOOR UNITY Series - High COPSpecificationsPUHY-EP YSJM-A (-BS)OUTDOOR UNITY Series - High COPSpecificationsMod

Page 42

OUTDOOR UNITY Series - High COPSpecificationsPUHY-EP YSJM-A(1) (-BS)PUHY-EP YSJM-A (-BS)OUTDOOR UNITY Serie

Page 43

OUTDOOR UNITY Series - High COPSpecificationsPUHY-EP YSJM-A(1) (-BS)OUTDOOR UNITY Series - High COPSpecificationsPUHY-EP YSJM-

Page 44

PUHY-EP YSJM-A(-BS)OUTDOOR UNITY Series - High COPSpecificationsPUHY-EP YSJM-A(1) (-BS)OUTDOOR UNITY Series - High COPSpecific

Page 45

Comparison of COP (energy efficiency) – 8HP system4.020R222.02.53.03.54.04.55.0Our equivalent product 10 years ago, PUHY-200YMF* Average COP of coolin

Page 46

O ptional parts>>4-way cassette type (PLFY-VBM/VCM)>>2-way cassette type (PLFY-VLMD)>>Ceiling concealed type (PEFY-VMH(S))>>Ce

Page 47

>>For PUHY seriesSnow HoodOPTIONAL PARTS FOR OUTDOOR UNITSOPTIONAL PARTS FOR CONTROLDescription Remarks ModelBranch pipe (Joint)Branch pipe (Hea

Page 48

CITY MULTIMEE11K010New publication effective Oct. 2011Specifications subject to change without noticeCM11AS-MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AI

Page 49

For the EnvironmentEnhancing environmental care (measures for the RoHS Directive and the refrigerant reduction)Every unit is in compliance with the Ro

Page 50 - O ptional parts

Remote ControllerIndividual Remote ControllerCentralized Remote ControllerPage 11 Page 12Remote ControllerThe need for control is paramount in order t

Page 51 - Maintenance equipment

System ControllerMELANSUse of our MELANS products enhances EFFICIENCY and QUALITY of air-conditioning, contributing to ENERGY SAVING and reduction in

Page 52

IndividualRemote ControllerWired MA remote controller PAR-30MAA• Backlit LCD (Liquid Crystal Display) Large, easy-to-see display Full-dot LCD displ