6 - 33
6 POSITIONING CONTROL
6.5 4 Axes Linear Interpolation Control
Linear interpolation control from the current stop position with 4 axes specified with the
positioning command of the PLC program is executed.
Items set using MT Developer
Common Arc Parameter block Others
Servo
instruction
Positioning
method
Number of
control axes
Parameter block No.
Axis
Address/travel value
Command s
eed
Dwell time
M-code
Tor
ue limit value
Auxiliar
oint
Radius
Central
oint
Control unit
S
eed limit value
Acceleration time
Deceleration time
Ra
id sto
deceleration time
Tor
ue limit value
Deceleration
rocessin
on sto
in
ut
Allowable error ran
e for circular inter
olation
S-curve ratio
Cancel
WAIT-ON/OFF
Speed change
ABS-4
Absolute
INC-4
Incremental
4
Valid
: Must be set
: Set if required
[Control details]
Positioning control which starts and completes the 4 axes simultaneously is executed.
4 axes linear interpolation
V
V
V
V
t
Axis 1
t
Axis 2
t
Axis 3
t
Axis 4
Travel value
Equal time
Exam
le