eth1000_large.jpg Setup and Programming of the FX3U-16CCL-M FX3U CC-LINK Master Module R72-11Z-SLSASG-028
4-2 Select Station Information and set the following for each Station number Figure 4.1.3 Station Information – CC-Link 4.2 CC-Link Remote I/
4-3 4.3 CC-Link Master Station Buffer Memory Locations The following shows the BFM locations that the PLC program can read from to get CC-Link N
4-4 4.4 Data Transfer per Remote Station Each Remote Station in the QSG occupies 1 Station in CC-Link V1.10 Mode. This includes 32 RX, 32 RY, 4
5-1 Chapter 5 GX Works2 Program Example 5.1 Initial Setup The demo program first configures the Number of Connected CC-Link Remote Modules
5-2 5.2 I/O and Data Word Transfer Function Blocks (FBs) Two FBs were created to transfer Digital I/O and Data Words to and from the network.
5-3 Figure 5.2.3 Digital I/O and Data Word Transfer Function Blocks in Function Block Selection Window The CCLinkDigitialIOComms Function Blo
5-4 5.3 Remote Analog Module Setup In the MAIN program when Remote Input 1 (M1000) goes ON it SETS the Enable Analog Output Bit (M10) and then
5-5 In the ANALOG program the first section initiates the 62DA Module then enables Output Channel 1. Figure 5.3.2 62DA Module Initialization a
5-6 The 62DA Module uses the following RX/RY and RWr/RWw Figure 5.3.3 62DA Module RX/RY I/O Points M1088 = RX(n+1)8 (Initial Data Processing R
5-7 Figure 5.3.4 62DA Module RWw and RWr Data Points D2008 = RWw (Analog Out Value) D2010 = RWw2 (Analog Enable) D2011 = RWw3 (Output Range)
i R72-11Z-SLSASG-028 Contents Contents ...
5-8 In the ANALOG program the second section initiates the 64AD Module then Reads Input Channel 1. Figure 5.3.5 64AD Module Initialization and
5-9 The 64AD Module uses the following RX/RY and RWr/RWw Figure 5.3.6 64AD Module RX/RY I/O Points M1120 = RX(n+1)8 (Initial Data Processing
5-10 Figure 5.3.7 64AD Module RWw and RWr Data Points D2012= RWwn (Analog Enable) D2013 = RWw(n+1) (Input Range) D1012 = RWr (Analog Input CH
6-1 Chapter 6 Other Master Features 6.1 Remote Slave Access Using FX3U-64CCL Modules and GX Works2 Software Remote Access is setup through the
6-2 First Select “Serial/USB” in the PC side I/F then Select “Other Station (Single Network)” Figure 6.1.2 Select “Other Station” from Other Stati
6-3 Input Head I/O number for the FX3U CC-Link Master and the Station Number of the Intelligent Device Station you want to program. Finally select
6-4 6.2 Remote Device V2.0 Support Version 2.0 Remote Devices or Intelligent Device Stations can be access by setting the Remote Stations Switch
Rev-1 Revisions February 2012 – Document Created and Published V1.0
ii R72-11Z-SLSASG-028 FURTHER READING REFERENCE LIST Mitsubishi FX3U-16CCL-M User's Manual JY997D43601a FX3U-16CCL-M Hardware Manual JY997D43
1-1 Chapter 1 Introduction This Quick Start Guide (QSG) provides instructions on how to set a FX3U CC-LINK Master Module (FX3U-16CCL-M) to talk wi
2-1 Chapter 2 System Overview This QSG was setup using the following test system. The FX3U CPU firmware must be Version 3.10 or greater for Autom
2-2 Special Note: Differences from FX2N CC-Link Master Item FX3U-16CCL-M FX2N-16CCL-M CC-Link version Ver.2.00 (Ver.1 supported) Ver.1.10 Acce
3-1 Chapter 3 Wiring and Hardware Setup 3.1 Master Remote Station CC-LINK Wiring This this example shows the Master and two Remote Stations.
3-2 Figure 3.2.2 Switch Settings On Hardware – Upper Remote Station, Lower Master
4-1 Chapter 4 GX Works2 CC-Link Network Setup 4.1 CC-Link Network Parameters Under the Project Manager Select Parameter Network Parameter C