Machine Specifications and Options
Options and retrofit specifications differ according
to country and region, so please check with your dealer.
◎
◎
◎
◎
◎
×
◎
○
◎
×
×
×
×
×
◎
×
◎
×
●
(Note 3)
○
×
×
◎
×
×
○
(Note 5)
◎
×
×
◎
◎
◎
◎
◎
×
○
○
●
×
×
×
×
×
◎
×
◎
●
●
(Note 2)
○
◎
×
×
×
×
×
◎
◎
●
◎
◎
◎
◎
×
100mm (3.9")
○
○
◎
×
◎
×
×
×
◎
×
◎
●
●
○
◎
●
×
×
×
×
×
◎
●
◎
◎
●
◎
×
150mm (5.9")
◎
○
◎
●
(Note 1)
×
◎
×
×
◎
×
◎
●
●
⃝
◎
●
×
×
×
×
×
◎
●
◎
×
×
×
×
×
⃝
○
×
×
×
×
×
×
◎
×
⃝
×
⃝
(Note 1)
⃝
×
×
◎
×
×
⃝
×
×
×
MA2000MEA8PVM ADVANCE EA12VM ADVANCE EA28VM ADVANCE EA8M EA30M EA40M EA50M
Machine specifications
MA2000MEA8PVM ADVANCE EA12VM ADVANCE EA28VM ADVANCE EA8M
◎
◎
●
×
×
×
⃝
○
×
×
×
×
×
×
◎
×
◎
×
×
⃝
×
×
◎
●
×
⃝
×
×
×
EA12DM
Options
◎
◎
×
◎
×
100, 150, 250mm (3.9", 5.9", 9.8")
◎
⃝
×
●
⃝
×
×
●
◎
●
◎
×
⃝
⃝
×
×
◎
●
●
×
×
×
×
◎
×
×
◎
×
100mm (3.9")
◎
⃝
×
●
◎
×
×
●
◎
●
◎
×
⃝
⃝
●
●
×
◎
●
×
×
×
×
◎
×
×
◎
×
200mm (7.9")
◎
⃝
×
●
×
×
◎
●
◎
●
◎
×
⃝
⃝
×
×
×
◎
●
×
×
×
×
EA30M EA40M EA50M
Main option correspondence table ◎Standard equipment ○Can be added after installation ●Cannot be added after installation ×Not available
Dimensions (W x D x H)
System total weight
Distance between table
and electrode mounting surface
Max. electrode weight
Method
Internal dimensions (W x D x H)
Fluid level adjustment range (from top of table)
Dimensions (W x D)
Max. workpiece dimensions (W x D x H)
Max. loading weight
T-slot
Capacity
Filtering method
Dielectric fluid temperature control unit
Machine
unit
Axis stroke (X x Y x Z)
Spindle
Working
tank
Ta bl e
(granite)
Dielectric
fluid
reservoir
(Note 1) The maximum electrode weight 500kg (227.0lb.) specifications are available as an option for the EA40.
EA12DM
2195 x 2512 x 2615
5400 (11880)
650 x 450 x 350
425 to 775
200 (440)
Automatic elevation tank
1100 x 810 x 450 (1400 x 900 x 550 : option)
100 to 400
850 x 600 (1100 x 750 : option)
1050 x 760 x 350
2000 (4400)
Three slots at 14-200 pitch
390 (100)
Three fine paper filters
Unit cooler
(86.4 x 98.9 x 103.0)
(25.6 x 17.7 x 13.8)
(16.7 to 30.5)
(43.3 x 31.9 x 17.7) (55.1 x 35.4 x 21.7)
(3.9 x 15.7)
(33.5 x 23.6) (43.3 x 29.5)
(41.3 x 29.9 x 13.8)
1460 x 1900 x 2020
2000 (4400)
300 x 250 x 250
223 to 473
25 (55)
Vertical front door
(automatic elevation tank: option)
770 x 500 x 230
90 to 180
500 x 350
740 x 470 x 130
550 (1210)
Two slots at 13-120 pitch
165 (44)
One fine paper filter
Unit cooler
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
(57.5 x 74.8 x 79.5)
(11.8 x 9.8 x 9.8)
(8.8 to 18.6)
(30.3 x 19.7 x 9.1)
(3.5 x 7.1)
(19.7 x 13.8)
(29.1 x 18.5 x 5.1)
Automatic filter
LCD display improves workability.
Workpiece coordinates can be set from manual
operation box.
Jog feedrate can be changed between 50 and 150%
with override function.
High-function manual operation box
Lighting (fluorescent lamp)
Dielectric fluid distributor
Programmable flushing nozzle selection
(automatic selection of dielectric fluid emission/suction)
Fluid treatment for multiple set-up machining etc (set either emission
or suction for coupler and sequentially execute with NC program).
(photo shows EA12V specifications)
Sprays dielectric fluid between workpiece
and electrode during pitch machining.
Distributes dielectric fluid into three flows
and sprays onto machining section.
Effective for medium-to large-sized EDMs which
discharge large quantities of sludge.
Reverse wash function is effective in achieving
high performance over a long time.
(Note 1) When the special working tank is at the lowest limit, the upper end of the
working tank is approx. 95mm (3.7") above the table.
(Note 2) The shuttle ATC cannot be used with the programmable flushing nozzle.
(Note 3) Six programmable flushing nozzles can be selected for MA2000.
Dimensions (W x D x H)
System total weight
Distance between table
and electrode mounting surface
Max. electrode weight
Method
Internal dimensions (W x D x H)
Fluid level adjustment range (from top of table)
Dimensions (W x D)
Max. workpiece dimensions (W x D x H)
Max. loading weight
T-slot
Capacity
Filtering method
Dielectric fluid temperature control unit
Machine
unit
Axis stroke (X x Y x Z)
Spindle
Working
tank
Ta bl e
(granite)
Dielectric
fluid
reservoir
6000 (13000)
400 x 300 x 300
153 to 453
(3R-MACRO)
50 (110)
Automatic elevation tank
650 x 500 x 340
100 to 300
550 x 470
600 x 450 x 250
700 (1540)
Four slots at 13-130 pitch
390 (100)
One fine paper filter
Unit cooler
2432 x 2421 x 2480
(95.7 x 95.3 x 97.6)
(15.7 x 11.8 x 11.8)
(6.0 to 17.8)
(25.5 x 19.6 x 13.3)
(3.9 x 11.8)
(21.6 x 18.5)
(23.6 x 17.7 x 9.8)
1750 x 2050 x 2335
3725 (8200)
400 x 300 x 300
270 to 570
50 (110)
Automatic elevation tank
850 x 600 x 350
100 to 300
700 x 500
800 x 550 x 250
700 (1540)
Three slots at 12-160 pitch
340 (90)
Two fine paper filters
Unit cooler
(68.8 x 80.7 x 91.9)
(15.7 x 11.8 x 11.8)
(10.6 to 22.4)
(33.5 x 23.6 x 13.7)
(3.9 x 11.8)
(27.5 x 19.6)
(31.4 x 21.6 x 9.8)
(70 (2.8) granite table
specifications)
(70 (2.8) granite table
specifications)
(70 (2.8) granite table
specifications)
Machine bodyDielectric fluid systemPower supply
Lubricant Automatic lubrication unit
Scale
Scale feedback specifications
Z-axis
XY-axis
Thermal displacement compensation system
Granite table
Column up specifications
High-function manual operation box
Lighting
Automatic elevation tank
Special working tank
Paper filter - 2-pc. specifications
Paper filter - 3-pc. specifications
Paper filter - 4-pc. specifications
Automatic filter
Cooler
Dielectric fluid automatic supply/drain
Emission/suction automatic changeover
Fluid system
Dielectric fluid distributor
FP80V
FP120V
FP60EA / MA
FP100EA
FP100B
(Note 4)
NP2 circuit
Narrow gap circuit
GF2 control
Main power
supply
Special
power
supply
Dielectric
filter
Working
tank
Machine bodyDielectric fluid systemPower supply
Lubricant Automatic lubrication unit
Scale
Scale feedback specifications
Z-axis
XY-axis
Thermal displacement compensation system
Granite table
Column up specifications
High-function manual operation box
Lighting
Automatic elevation tank
Special working tank
Paper filter - 2-pc. specifications
Paper filter - 3-pc. specifications
Paper filter - 4-pc. specifications
Automatic filter
Cooler
Dielectric fluid automatic supply/drain
Emission/suction automatic changeover
Fluid system
Dielectric fluid distributor
FP80V
FP120V
FP60EA / MA
FP100EA
FP100B
(Note4)
NP2 circuit
Narrow gap circuit
GF2 control
Main power
supply
Special
power
supply
Dielectric
filter
Working
tank
(Note 4) FP100EA power supply.
(Note 5) The maximum working tank elevation position will change if the SP
power supply is equipped.
(The maximum workpiece height will be 200mm.)
1625 x 1717 x 2000
2000 (4400)
300 x 250 x 250
200 to 450
25 (55)
Vertical front door
770 x 500 x 250
110 to 200
500 x 350
740 x 470 x 150
550 (1200)
Three slots at 12-100 pitch
196 (50)
One paper filter
Fan cooler
(63.9 x 67.5 x 78.7)
(11.8 x 9.8 x 9.8)
(7.8 to 17.7)
(30.3 x 19.6 x 9.8)
(4.3 to 7.8)
(19.6 x 13.7)
(29.1 x 18.5 x 5.9)
6860 (15100)
700 x 500 x 350
300 to 650
200 (440)
Vertical front door
1280 x 850 x 450
190 to 400
1100 x 750
1230 x 800 x 350
2000 (4400)
Four slots at 14-180 pitch
800 (210)
One paper filter
Unit cooler
2520 x 3055 x 2495
(99.2 x 120.2 x 98.2)
(27.5 x 19.6 x 13.7)
(11.8 to 25.5)
(50.4 x 33.4 x 17.7) (XK140A)
(4.3 to 15.7)
(43.3 x 29.5)
(48.4 x 31.5 x 13.8)
12000 (26000)
1000 x 600 x 450
450 to 900
300 (660)
(500 (1100))(Note 1)
Automatic vertical front door
1600 x 1100 x 500
200 to 450
1400 x 950
1500 x 1000 x 400
5000 (11000)
Five slots at 14-200 pitch
1900 (500)
Two paper filters
Unit cooler
3050 x 3633 x 3140
(120.0 x 143.0 x 123.6)
(39.3 x 23.6 x 17.7)
(17.7 to 35.4)
(62.9 x 43.3 x 19.6) (XK170)
(7.8 to 17.7)
(55.1 x 37.4)
(59.0 x 39.3 x 15.7)
20000 (44000)
1500 x 600 x 600
500 to 1100
500 (1100)
Automatic vertical front door
2500 x 1600 x 850
400 to 800
2000 x 1350
2400 x 1500 x 750
10000 (22000)
Seven slots at 14-200 pitch
5200 (1370)
Four paper filters
Unit cooler
4280 x 4295 x 4100
(168.5 x 169.0 x 161.4)
(59.0 x 23.6 x 23.6)
(19.6 to 43.3)
(98.4 x 62.9 x 33.4) (XK270)
(15.7 to 31.4)
(78.7 x 53.1)
(94.4 x 59.0 x 29.5)
Vertical front door
One paper filter
1840 x 1960 x 2375
2900 (6300)
400 x 300 x 300
300 to 600
50 (110)
1050 x 700 x 450
180 to 400
700 x 500
1000 x 650 x 350
1000 (2200)
Three slots at 12-160 pitch
500 (130)
Unit cooler
(72.4 x 77.1 x 93.5)
(15.7x 11.8 x 11.8)
(11.8 to 23.6)
(41.3 x 27.5 x 17.7)
(7.0 to 15.7)
(27.5 x 19.6)
(39.3 x 25.5 x 13.7)
Standard manual
operation box
TF20
Dielectric fluid temperature controller
(unit cooler)
Dielectric fluid temperature controller
(for booster power)
Programmable flushing nozzle selection,
automatic changeover
SP power supply
(for tungsten carbide machining)
Dielectric fluid temperature controller
(unit cooler)
Dielectric fluid temperature controller
(for booster power)
Programmable flushing nozzle selection,
automatic changeover
SP power supply
(for tungsten carbide machining)
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[mm (in)]
[mm (in)]
[mm (in)]
[mm (in)]
[kg (lb.)]
[
r
(gal.)]
[mm (in)]
33 34
Product Line-up
Machining Samples
Total Solutions
Machine Specifications
and Options
Advance Series
Functions and Features
EA Series Functions
and Features
Advance Series
Product Introduction
MA, EA Series
Product Introduction
Advance Control Unit
Tooling
64-bit Control Unit
Power Supply/Control
Specifications
Preparation for
Machine Installation
Precautions
Commentaires sur ces manuels